EasyManuals Logo

Gree GWH09QA-K6DNB4A/I User Manual

Gree GWH09QA-K6DNB4A/I
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
106
Installation and Maintenance
Service Manual
4. Malfunction of Zero-crossing Inspection Circuit Malfunction of the IDU Fan Motor U8
Main detection points:
● Instant energization afte de-energization while the capacitordischarges slowly?
● The zero-cross detectioncircuit of the mainboard is dened abnormal?
Malfunction diagnosis process:
Turn power off for
1minute,the turn
back on
The unit returns to normal.
Conclusion:U8 is displayed due to
power off/on while the
capacitor discharges slowly.
U8 is still
displayed
The zero-cross detection circuit
of the mainboard is dened
abnormal.Replace the mainboard
with the same model
Yes
No
Start
End

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH09QA-K6DNB4A/I and is the answer not in the manual?

Gree GWH09QA-K6DNB4A/I Specifications

General IconGeneral
BrandGree
ModelGWH09QA-K6DNB4A/I
CategoryAir Conditioner
LanguageEnglish

Related product manuals