What to do if Gree GWH09YC-K6DNA1A Air Conditioner has abnormal sound inside compressor?
- JJenny PhamSep 23, 2025
If there is an abnormal sound inside your Gree Air Conditioner's compressor, change the compressor.

What to do if Gree GWH09YC-K6DNA1A Air Conditioner has abnormal sound inside compressor?
If there is an abnormal sound inside your Gree Air Conditioner's compressor, change the compressor.
What to do if the Gree GWH09YC-K6DNA1A remote controller does not receive signals?
If your Gree Air Conditioner's remote controller isn't sending signals, first press the manual switch button AUTO. If there's no response, check using the methods described earlier. If it runs normally after pressing the button, verify that the installation position and the connection wire of the reception head are correct. Also, check for receiver issues like looseness or poor connection and ensure the installation position and connection wire of the reception head are correctly placed. If the connections are correct, the receiver might be broken, consider replacing the receiver or the remote controller.
What to do if Gree GWH09YC-K6DNA1A does not react after it is powered?
If your Gree Air Conditioner isn't responding after you power it on, check these potential causes: * Ensure the power plug is properly plugged in and has a firm connection. * If the controller fuse is burnt out, replace it. * Check the transformer connection for looseness or bad contact; fasten the wiring and measure the transformer's output voltage. If the voltage is incorrect, replace the transformer.
Why does the Gree GWH09YC-K6DNA1A breaker trip after a few minutes?
If the breaker trips a few minutes after turning on your Gree Air Conditioner, it could be due to a malfunction in the circuit or a part of the air conditioner. Measure the insulation resistance or systematically eliminate the malfunction. If the breaker itself is faulty, replace it.
What to do if Gree GWH09YC-K6DNA1A power voltage is too low?
If the power voltage is too low for your Gree Air Conditioner, check the cause, improve the power supply condition, and consider adding a stabilized voltage power supply.
What to do if there is a foreign object in Gree GWH09YC-K6DNA1A Air Conditioner indoor unit?
If there is a foreign object in your Gree Air Conditioner's indoor unit, take it out.
How to fix Gree GWH09YC-K6DNA1A Air Conditioner refrigerant pipe joint wrap?
If the wrap of the refrigerant pipe joint in your Gree Air Conditioner isn't close enough, re-wrap it and make it tight.
What to do if Gree Air Conditioner indoor unit fan contacts other parts?
If the fan of the indoor unit in your Gree Air Conditioner is contacting other parts, adjust the fan location.
How to fix Gree GWH09YC-K6DNA1A Air Conditioner four-way valve malfunction?
If the four-way valve in your Gree Air Conditioner is malfunctioning, replace it.
What to do if Gree GWH09YC-K6DNA1A Air Conditioner motor is damaged?
If the motor in your Gree Air Conditioner is damaged, replace the motor.