83
Installation and Maintenance
Service Manual
12. Remove magnet coil
Remove the screw fixing the magnet coil and then
remove the coil.
magnet coil
13. Remove valves and 4-way valve subassembly
4-way valv e
14. Remove compressor
Remove the foot nuts on the compressor and then
remove the compressor.
compresso r
Cut off the welded pipe of the 4-way valve
component to the gas valve ,the condenser assy
and compressor, and then remove the 4-way valve.
Remove the screws fixing the valves, Cutting the
pipeline of welding the gas valve and the liquid
valve, and remove the gas valve and the liquid
valve.
liquid valv e
gas valv e
foot nuts
Note:
When cutting weld, wrap the valve with wet cloth
completely to avoid damaging the valve due to
high temperature.
ProcedureSteps