EasyManua.ls Logo

Gree GWH12AGC-K6DNA1F/I - Installation Steps Part 3

Gree GWH12AGC-K6DNA1F/I
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Outdoor unit connection
N(1)
blue
2
black
3
brownyellow-
green
Outdoor unit connection
N(1)
blue
2
black
3
brown
yellow-
green
07K09K
GWH12AGB-K6DNA1A
GWH12AGB-K6DNA4A
18K24K:
GWH12AGC-K6DNA1A
GWH09AGC-K6DNA1F
GWH12AGC-K6DNA1F
1.
3.
5.
upper hook
indoor unit
band
The power cord and control wire can't be crossed or
winding.
The drain hose should be bound at the bottom.
2.
lower hook of
wall-mounting frame
indoor
wall pipe
3.
4.
4.
Step 9:
Hang the indoor unit
2.
outdoor
sealing gum
3.
4.
gas
5.
pipe
liquid pipe
drain hose
Step 8:
Bind up pipe
1.
indoor and
outdoor power cord
The wiring board is for reference only, please refer
to the actual one.
9
Do not bend the drain hose too excessively in order
to prevent blocking.
connection pipe
drain hose with the band.
drain hose
band
indoor power cord
Put the bound pipes in the wall pipe and then
Bind up the connection pipe, power cord and
NOTICE
make them pass through the wall hole.
Hang the indoor unit on the wall-mounting
frame.
Stuff the gap between pipes and wall hole
with sealing gum.
Fix the wall pipe.
Check if the indoor unit is installed firmly and
closed to the wall.
NOTICE
NOTICE
Remove the wire clip; connect the power conn-
ection wire to the wiring terminal according to
the color; tighten the screw and then fix the po-
wer connection wire with wire clip.
Bind them evenly.
The liquid pipe and gas pipe should be bo-
und separately a t the end.
Put wiring cover back and then tighten the screw.
Close the panel.
Reserve a certain length of drain hose and
power cord for installation when binding th-
em. When binding to a certain degree, sep-
arate the indoor power and then separate
the d
rain hose.

Related product manuals