6FKHPDWLF'LDJUDP
*:+1%.11($,
1
2
3
45 67 89
10
11
12 13 14
●TOP VIEW
●BOTTOM VIEW
1 Compressor control relay K1
2 Fuse
3
Interface of health function neutral
wire and control relay K116
4 Indoor fan control port
5 Auxiliary heating relay K113, K112
6
4-way valve control port and
control relay K115
7
Outdoor fan control port and
control relay K113
8 Auto button
9 Up & down swing control port
10 Indoor fan feedback interface
11 Display control port
12 Pipe temp sensor interface
13 Ambient temp sensor interface
14 High frequency transformer T1