38
Sleep Mode 3 (Customized Cycle)
You will be required to enter 8 room setpoint values for 8 hours of runtime.  e last room setpoint value will be main-
tained until Sleep Mode is canceled.
In Sleep Mode 3, press the “Turbo” button to enter setup mode.  e remote controller will display “1:00” in the time lo-
cation. Use the “+” and “-” buttons to select the desired room setpoint for the 1st hour of runtime, then press the “Turbo
button to save the data.
e remote controller will display “2:00”. Once again, use the “+” and “-” buttons to select the desired room setpoint for the
second hour of run time. Press the “Turbo” button to save the data.
Repeat this procedure for the remaining hours (total of 8). A er all 8 settings have been saved, the remote controller will
automatically revert back to the standard time and temperature display.
At anytime, you may press the “ON/OFF, “MODE”, “TIMER, “SLEEP” or “TURBO” buttons to cancel the Sleep Mode 3
7) Indoor Fan Control
e indoor fan can be set to Ultra High, High, Med, Low and Auto with the remoter controller.
In auto mode, the following speeds will be set:
Cooling Mode
a) T
indoor
ambient >= T
setpoint
+ 2 F
,
fan will run on high speed
b) T
setpoint
- 2 F < T
indoor
ambient < T
setpoint
+ 2 F
,
fan will run on medium speed
c) T
indoor
ambient <= T
setpoint
- 2 F
,
fan will run on low speed
System Operation 18,000/24,000 btuh Models, cont.
Other Controls
Product Introduction
T
preset
T
preset
-2 F
T
preset
+ 2 F
Fan Speed High Med. Low O
T
amb.