64
Installation and Maintenance
Service Manual
6.Remove 4-way valve assy
Discharge the refrigerant completely; unsolder the
pipelines connecting the compressor and the
condenser assy, and then remove the 4-way valve
assy.(Recover the refrigerant before unsoldering)
Discharge the refrigerant completely; unsolder the
pipelines connecting the compressor and the
condenser assy, and then remove the 4-way valve
assy.
Remove the screws fixing the isolation sheet and
then remove the isolation sheet.
7.Remove compressor
8.Remove chassis sub-assy and condenser sub-assy
4-way valve assy
compressor
isolation sheet