EasyManua.ls Logo

Gree GWHD14NK3BO - Troubleshooting Guide; Malfunction Diagnosis and Resolution

Gree GWHD14NK3BO
107 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
61
9. Troubleshooting
9.1 Malfunction Indicator
Note: : off : on Ƽ: blink
When several malfunctions occur at the same time, they will be displayed in circulation and every malfunction is
displayed for 5s.
NO Malfunction description LED1 LED2 LED3 LED4
0 Normal stop
1 Compressor run ● ○
2 Compressor overload protection Ƽ
3 Discharge protection
4 Outdoor unit overload protection
5 High pressure protection Ƽ
6 Over current protection Ƽ
7 IMP protection Ƽ
8 IMP over heating protection Ƽ Ƽ
9 PFC protection (including PFC overheating protection)
10 Phase current protection
11 Over voltage protection Ƽ
12 Insufficient voltage protection
13 Start failure
14 Compressor desynchronizing Ƽ
15 Compressor phase-lacking protection Ƽ
16 Compressor phase current detection malfunction Ƽ
17 Memory chip mistake Ƽ Ƽ
18 DC power supply circuit-short Ƽ
19 Defrosting Ƽ
20 Oil return Ƽ Ƽ
21 Complete unit frequency restriction protection Ƽ
22 Complete unit frequency dropping protection Ƽ
23 Unit A frequency restriction or frequency dropping protection Ƽ Ƽ
24 Unit B frequency restriction or frequency dropping protection Ƽ Ƽ
25 Unit C frequency restriction or frequency dropping protection Ƽ Ƽ
26 Unit D frequency restriction or frequency dropping protection Ƽ Ƽ Ƽ
27 Outdoor ambient temperature sensor protection
28 Outdoor tube temperature sensor protection
29 Discharge temperature sensor protection Ƽ
30 IPM thermal resistance malfunction
31 Unit A liquid pipe temperature sensor malfunction
32 Unit A gas pipe temperature sensor malfunction Ƽ
33 Unit B liquid pipe temperature sensor malfunction Ƽ
34 Unit B gas pipe temperature sensor malfunction Ƽ
35 Unit C liquid pipe temperature sensor malfunction Ƽ Ƽ
36 Unit C gas pipe temperature sensor malfunction
37 Unit D liquid pipe temperature sensor malfunction
38 Unit D gas pipe temperature sensor malfunction Ƽ
39 Unit A mode conflict
40 Unit B mode conflict
41 Unit C mode conflict Ƽ
42 Unit D mode conflict Ƽ

Table of Contents