5
Technical Information
Service Manual
The above data is subject to change without notice. Please refer to the nameplate of the unit.
Outdoor
Unit
Cross-sectional Area of Power Cable Conductor mm
2
2.50 2.50
Recommended Power Cable(Core) N 3 3
Connection Pipe Connection Method - Flare Connection Flare Connection
Not Additional Gas Connection Pipe Length m 5 5
Connection Pipe Gas Additional Charge g/m 20 20
Outer Diameter of Liquid Pipe(GREE Allocation)
(Metric)
mm Φ6 Φ6
Outer Diameter of Gas Pipe(GREE Allocation)
(Metric)
mm Φ9.52 Φ9.52
Connection Pipe Max. Height Distance(indoor and
indoor)
m 5 10
Max. equivalent connection pipe length(outdoor to
last indoor)
m 10 20
Connection Pipe Max. Length Distance(total lenght) m 20 60