6
Technical Information
Service Manual
Model GWHD(28)NK3FO
Product Code CB228W03600/CB228W03601
Power
supply
Rated Voltage V~ 220-240V
Rated Frequency Hz 50
Phases 1
Cooling capacity(max~min) W 8000(2200~10000)
Heating capacity(max~min) W 9300(2800~11000)
Cooling Power Input(max~min) W 2490(650~4550)
Heating Power Input(max~min) W 2580(980~3950)
Cooling Current Input A 11.05
Heating Current Input A 11.45
Rated Power Input W 4550
Rated Current A 20.19
SEER W/W 5.1
SCOP W/W 3.8
Outdoor
Unit
Compressor Trademark ZHUHAI LANDA COMPRESSOR CO.,LTD
Compressor Model QXAS-D23zX090B
Compressor Refrigerant Oil Type RB68EP
Compressor Type Rotary
L.R.A A /
Compressor Rated Load Amp (RLA) A 11.5
Compressor Power Input W 2550
Compressor Thermal Protector 1NT11L-6233
Throttling Method Electron expansion valve
Cooling Operation Ambient Temperature Range
O
C -15~48
Heating Operation Ambient Temperature Range
O
C -15~24
Condenser Material Aluminum Fin-copper Tube
Condenser Pipe Diameter mm Φ7
Rows-Fin Gap(mm) mm 2-1.4
Coil length (l) X height (H) X coil width (L) mm 982.2X38.1X748
Fan Motor Speed (rpm) (H/M/L) rpm 710
Output of Fan Motor W 90
Fan Motor RLA A /
Fan Motor Capacitor μF /
Air Flow Volume of Outdoor Unit m
3
/h 4000
Fan Type-Piece Axial-ow
Fan Diameter mm Φ552
Defrosting Method Automatic Defrosting
Climate Type T1
Isolation I
Moisture Protection IP24
Permissible Excessive Operating Pressure for the
Discharge Side
MPa 4.3
Permissible Excessive Operating Pressure for the
Suction Side
MPa 2.5
Dimension (WXHXD) mm 1001X790X427
Dimension of Package (LXWXH) mm 1080X485X840
Dimension of Package(LXWXH) mm 1083X488X855
Net Weight kg 69
Gross Weight kg 74
efrigerant Charge R410A
Refrigerant Charge kg 2.20