Gree MULTI18HP230V1CO Installation Manual

Gree MULTI18HP230V1CO
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Standard Wrench
Adjustable/Crescent Wrench
Torque Wrench
Hex Keys or Allen Wrenches
Drill & Drill Bits
Hole Saw
Pipe Cutter
Screw drivers (Phillips & Flat blade)
Manifold and Gauges
Level
R410A Flaring Tool
Clamp on Amp Meter
Vacuum Pump
Safety Glasses
Work Gloves
Refrigerant Scale
Micron Gauge
SUGGESTED TOOLS
5
TROUBLESHOOTING
PROBLEM
Water leaking from the indoor
unit into the room.
Wireless remote controller
does not work.
The unit will not deliver air.
Moisture or condensation
on the discharge air louvers
or outlet vents.
Mode Conflict (E7) is displayed.
CAUSE/SOLUTION
Cause:
While it is normal for the system to generate condensate water in cooling
mode, it is designed to drain this water via a condensate drain system to a safe location.
Solution: If water is leaking into the room, it may indicate one of the following.
The indoor unit is not level right to left. Level indoor unit.
The condensate drain pipe is restricted or plugged. All restrictions must
be removed to allow continuous drainage by gravity.
If problem persists, contact a qualified service professional for assistance.
Cause: There are a number of possible reasons.
Solution: Check the following:
The remote controller was not matched to the indoor unit.
See matching instructions.
The batteries might be low. Change the batteries.
The remote controller must be within 25 ft. (7.5 m) with no obstructions
of the indoor unit. If remote controller needs to be replaced, contact a
qualified service professional for assistance. In the meantime, use the
Aux button to operate the system.
Cause: There are a number of system functions that will prevent air flow.
Solution: Check for the following:
In heating mode, the indoor fan may not start for three minutes if the
room temperature is very low. This is to prevent blowing cold air.
In heat mode, if the outdoor temperature is low and humidity is high,
the system may need to defrost for up to 10 minutes before beginning
a heating cycle.
In dry mode, the indoor fan may stop for up to three minutes during the
compressor off delay.
Otherwise, you should contact a qualified service professional for assistance.
Cause: It is normal for the system to develop condensation or moisture on the
discharge air louvers when cooling warm humid air for a long period of time.
Solution: The condensation or moisture will disappear as the system cools and
dehumidifies the room space.
Cause: When indoor units have different mode settings (for example, some set
to Cool, others set to Heat, Fan Only or Dry) it creates a Mode Conflict.
Solution: Be sure that all indoor units are set to the same mode (i.e., Cool, Heat,
Fan Only or Dry). Once this is done, the Mode Conflict status will disappear.
36
TWD-1518 multi21+ install_printer.qxp_Layout 1 3/22/17 9:41 AM Page 13

Other manuals for Gree MULTI18HP230V1CO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree MULTI18HP230V1CO and is the answer not in the manual?

Gree MULTI18HP230V1CO Specifications

General IconGeneral
BrandGree
ModelMULTI18HP230V1CO
CategoryAir Conditioner
LanguageEnglish