14
Technical Information
Service Manual
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould.
X-FAN function
:
Hold fan speed button for 2s in COOL or DRY mode, the icon “ ” is displayed and the indoor fan will
continue operation for a few minutes in order to dry the indoor unit even though you have turned off the unit. After energization,
X-FAN OFF is defaulted. X-FAN is not
available in AUTO, FAN or HEAT mode.
●
Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for a few
minutes. at low speed. In this period, Hold fan speed button for 2s to stop indoor fan directly.
●
Having set X-FAN function off: After turning off the unit by pressing ON/OFF button, the complete unit will be off directly.
●
This button is used for setting Fan Speed in the sequence that goes from AUTO,
,
FAN
:
Auto
Medium speedLow-Medium speedLow speed
High speedMedium-High speed
to
then back to Auto.
,
,,
6
Pressthis buttontoset up &downswing angle,whichcircularlychangesasbelow
:
OFF
This remote controller is universal . If any command , or is sent out, the unit will carry
indicates the guide louver swings as:
Press this button to turn on I FEEL function. The unit automatically adjust temperature according to the sensed temperature.
Press this button again to cancel I FEEL function.
I FEEL:
SWING:
7
out the command as
P
ress this button to achieve the on and off of healthy and scavenging functions in operation status.Press this button for the
first time to start scavenging function; LCD displays“ ”. Press the button for the
second time to start healthy and
scavenging functions
simultaneously; LCD displays“ ” and “ ” .
Press this button for the third time to quit healthy
and scavenging functions simultaneously. Press the button for the fourth time to start healthy
function; LCD display “ ”
Press this button again to repeat the operation above.
NOTE: This function is applicable to partial of models.
/
8
SLEEP:
9
Press this button,can select Sleep 1( ), Sleep2( ),Sleep 3( )and cancel the Sleep, circulate between these,
afterelectrified, Sleep Cancel is defaulted.
Sleep 1isSleepmode1,inCool, Dehumidify modes: sleepstatus afterrun forone hour,the main unit settingtemperature will increase 1
ƽ
ƽ
đ
,setting temperatureincreased 2 đ,the unitwill runatthis
settingtemperature;InHeat mode:sleep status afterrun for one hour, the
temperature will decrease 1
đ,2 hours, setting temperaturewilldecrease2đ,thenthe unit will runatthissetting
temperature.
ƽ Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve.
Sleep 3- the sleep curve setting under Sleep mode by DIY:
(1)Under Sleep 3mode, press"Turbo" buttonfor alongtime, remote control enters into user individuation sleep
thetimeofremotecontrol will display"1 hour ", thesetting temperature "88" will
setting status, at this time,
(2) Adjust "+" and "-" button, could change the corresponding settingtemperature,after adjusted,press "Trubo "button for confirmation
(3) At this time, 1 hour will be automatically increased at the timer postion on the remote control, (that are "2 hours " or "3 hours "
(4)Repeatthe abovestep(2)
Њ
(3) operation,until 8hours temperature setting finished, sleep curve setting finished, at this time,
theremotecontrol will resume theoriginaltimer display;
curveand blink(Thefirst entering will display
displaythe correspondingtemperatureoflast settingsleep
accordingtothe initialcurve settingvalue of originalfactory);
or "8 hours "), the place of setting temperature "88" will display the
corresponding temperature of last setting sleep curve and blink;
temperature display will resume to original setting temperature.
ƽ
Sleep3- the sleep curve setting under SLEEP mode by DIY could be inquired: