I
nstallation / Operating Instruction
for Fused Timer Connection Unit - 7 Day
- Model: T205
OPERATING INSTRUCTIONS
‘ON’ Indicator
Programme
Button
Time
Button
Fuse
Holder
Front Cable
Entry
Reset
Button
‘+’ and ‘-’
Button
Dia.1
Dia.2
Dia.3
Dia.4
Note: Time setting is 24 hour mode.
1. Press the ‘TIME’ button for 2 seconds. Day of
week will start flashing (example shows 7 Day
setting Dia.3)
2. Use the ‘+’ or ‘-’ button to change the
display to the correct day of the week.
3. Press the ‘TIME’ button and the hour digits will
flash.
(Dia.4)
4. Use the ‘+’ or ‘
-’ button to set the hours.
5. Press the ‘TIME’ button and the minute digits will
flash. (Dia.5)
6. Use the ‘+’ or ‘-’ button to set the minutes.
7. Press the ‘TIME’ button to save the setting
and return to operating mode.
1. To fully reset this unit press the recessed
‘Reset’ button with a insulated blunt probe.
2. A full display will show when the battery is
charged, then revert to the default screen
( : ). No display indicates that the
battery requires charging for a minimum 3
hour period. (Dia.2 - Full display)
Please read the instructions fully before attempting installation.
IMPORTANT
T
his unit should be installed by a competent person
in accordance with the current IET Wiring Regulations.
If in doubt consult a qualified electrician
.
Connection Unit must not be mounted on a flammable surface.
Ensure that the Connection Unit does not come into contact with
any combustible materials such as towels or bedding.
Ensure at least a 300mm air space is allowed around the
Connection Unit.
A 12mm pattress is provided if extra spacing is required.
Twin Earth terminal provided.
Note: Where earthing termination is required this must be connected to
a earth terminal as provided in a metal back box.
Dia.22
Note: Battery is fully charged after 14.5 hours.
The non-replaceable, fully charged battery, will retain any program information
for a period of 700 hours should their be power loss or the unit switched off with
the manual double pole switch.
Display is not visible during this period unless a button is pressed.
S
Note: Pressing the ‘PROG’ and ‘TIME’ (combinations of buttons) to exit the summer mode.
WIRING DIAGRAM
BATTERY BACK UP/LIFE
Display: LCD
Working Voltage: 230V-50Hz
Rated Impulse Voltage: 4,000V
Operating Temp: -5°C to +40°C
Operation: Integrated Control
Max Load:
Resistive - 13A
Inductive - 6A
Working Environment: Indoor use only
Pollution Degree: 2
Manual Switch Type: Double Pole Switch
Timer Switch Type: Relay (Single Pole)
Cord Anchorage: Cable Dia: 4.6mm to 10.4mm
Terminal Capacity Cable Size: 3 x 1.0mm
2
to 3 x 2.5mm
2
Conforms to: BS 5733:2010+A1:2014
BS EN 60730-1:2016+A1:2019
BS EN IEC 60730-2-7:2020
TECHNICAL INFORMATION
(Example: the clock will change to ‘11.00’, if the time is ‘10.00’ now
press “PROG’ and ‘TIME’.)
T205
Supply
Load
TIMER
13A Fuse
Manual Double Pole Switch
L
N
N
L
Issue no: 706876
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
info@greenbrook.co.uk
www.greenbrook.co.uk
GUARANTEE
Your GreenBrook Fused Timer Connection Unit
is guaranteed for 1 year from
the date of purchase.
This is in addition to your statutory rights.
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
Time Switch Relay
(Single Pole)
Manual Double
Pole Switch
S
UMMER MODE
1. In operating mode, pressing the ‘PROG’
and ‘TIME’ (combination of buttons) to set
t
he summer mode. The clock will forward
on one hour (showing the icon Dia.22).
NOTE:
Product & Packaging Disposal
When disposing of this item and its packaging please follow local regulations
and use an appropriate waste disposal centre.
See GreenBrook website for further details.
RESET THE DEVICE
SETTING THE DAY OF THE WEEK & TIME
T205 Ins Sept 21_Layout 1 09/06/2022 15:40 Page 1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Green Brook T205 and is the answer not in the manual?

Green Brook T205 Specifications

General IconGeneral
BrandGreen Brook
ModelT205
CategorySecurity Sensors
LanguageEnglish

Related product manuals