Modular Make-Up Air Unit
Model DGX
• Direct Gas-Fired Heating
• Evaporative • Chilled Water • DX Cooling
March
2007
Question and Answer IconNeed help?

Do you have a question about the Greenheck Modular Make-Up Air Unit DGX and is the answer not in the manual?

Greenheck Modular Make-Up Air Unit DGX Specifications

Gas Train and Controls IconGas Train and Controls
maximum gas train capacity400, 000 Btu/hr
gas train ignition systemdirect spark ignition
safety shutoff valve control signal120 VAC
Fan Specifications IconFan Specifications
fan typecentrifugal
fan inlet typedouble width, double inlet
fan bearing life100, 000 hours
Cooling Coil IconCooling Coil
coil typedirect expansion or chilled water
coil fin density12 fpi or less
drain pan extension12 inches
Evaporative Cooling Section IconEvaporative Cooling Section
evaporative cooling media depth12 inches
evaporative cooling media fire ratingUL 900 class II
wind load resistance25 PSF

Summary

Product Features

Durable Construction

Highlights G90 galvanized steel construction and lifting lugs for robust durability.

Direct Gas-Fired System

Details high-quality burners, electronic modulation, and flame safeguard for efficient heating.

Control Center

Outlines standard control components like voltage, motor starter, and disconnect switch.

Vibration Isolators

Explains neoprene or spring isolators for minimizing noise transmission into the building.

Reliable Fan Performance

Discusses fan wheel construction, balancing, and performance ratings from a test chamber.

Access Panels

Notes large panels for easy inspection and maintenance of internal components.

Factory Wired and Tested

Confirms units are tested prior to shipment for proper operation of all systems.

Variable Make-Up Air Options

Variable Volume

Tracks make-up air volume with exhaust for energy savings.

Variable Volume Airflow Control Strategies

Details four methods for controlling make-up air volume by varying fan speed.

Burner By-Pass Damper

Maintains pressure drop across the burner as air volumes change for proper combustion.

Recirculation

Allows recirculation of space air with outdoor air for heating needs.

Recirculation Airflow Control Strategies

Lists four methods for controlling recirculated air to outdoor air ratio via dampers.

Temperature Control

Covers three options for heat control: Discharge, Space, and DDC Interface.

Discharge Control

Controls gas valve based on fan discharge sensor for desired temperature.

Room Control

Uses a thermostat to maintain desired room set point via discharge temperature.

DDC Interface Control

Allows external signal for modulating burner output to satisfy monitored conditions.

Installation Options

Roof Mounted Installation

Details stand-alone installation options for downblast, upblast, or horizontal discharge.

Combination Package

Simplifies installation and reduces labor costs for kitchen ventilation applications.

Thru-Wall Installation

Describes an option ideal when roof penetration is not desirable for specific housing sizes.

Accessories

Remote Control Panels

Offers various remote control panels with combinations of switches, thermostats, and indicators.

Special Coatings

Permatector™ coating and decorative paints available for durability and aesthetics.

Roof Curbs

Factory-provided roof curbs ensure compatibility with the make-up air unit and roof curb.

Duct Adapter

Allows for easy alignment of the supply duct connection with factory supplied roof curbs.

V-Bank Filter Section

Available with washable aluminum mesh or 2-inch 30% efficient disposable filters.

Weatherhood

Options include standard, filtered, and louvered intake hoods with birdscreen or mesh filters.

Motorized Dampers

Intake or discharge dampers prevent backdrafts when the supply fan is not in operation.

Fiberglass Insulation

One inch fiberglass insulation lines the housing to prevent condensation and provide acoustical barrier.

Double Wall Construction

Features an interior metal liner to isolate fiberglass insulation from the airstream.

Spring Vibration Isolation

Spring blower vibration isolators are an alternative to neoprene isolators.

Exhaust Fan Starter(s)

Factory mounted starters allow electrical interlock between supply and exhaust fans.

Dirty Filter Switch

Monitors filter pressure drop and indicates when cleaning or replacement is needed.

Freeze Protection

Automatically shuts down the supply fan when discharge temperature drops below a set point.

Inlet Air Sensor - Heat

Turns heating on/off based on the outdoor air temperature for efficiency.

Discharge Diffuser

Available as 3-way for horizontal or 4-way for downblast discharge.

Service Receptacle

External 115 volt GFCI outlet for service personnel convenience.

Auxiliary Contacts

Provide normally open/closed contacts for supply fan status and interlocks.

Air Performance

Typical Specifications

General

Specifies make-up air unit manufactured by Greenheck, meeting ETL and CSA standards.

Gas Train and Controls

Details direct gas-fired system with adjustable burners, ignition, fault indicator, and Maxitrol control.

Unit Casing and Frames

Describes internal frame construction of G90 galvanized steel with standing seams for weather protection.

Insulation

Specifies 1-inch fiberglass insulation meeting NFPA 90A and UL 181 erosion requirements.

Fan Section

Covers double width, double inlet centrifugal fans mounted on a common base with lubricated bearings.

Motors and Drives

Details energy-efficient motors, permanently lubricated, and drives sized for 150% of driven horsepower.

Electrical

Outlines prewired components, UL listing, NEC compliance, motor starters, and overload protection.

Filter Section

Designed for velocities under 550 fpm, using 2-inch washable aluminum mesh or disposable filters.

Weatherhood

Specifies G90 galvanized steel construction with birdscreen mounted at the intake.

Recirculation (optional)

Recirculation airflow controlled by return damper position, not permitted across the burner.

Variable Volume (optional)

Volume varied by 2-speed motor or VFD; includes self-adjusting burner bypass damper.

Cooling Coil (optional)

DX or chilled water coils with copper tubes, aluminum fins, and sloped drain pans.

Evaporative Cooling Section (optional)

Includes galvanized steel housing, mesh filters, and a stainless steel evaporative cooling module.