980 Hydraulic Power Pump
Setup
Hydraulic Connection
1. Clean all couplers, threaded fittings, ports and the
area around all ports.
2. Remove any dust plugs from couplers.
3. Hand-tighten all couplings firmly (until all threads
are fully engaged). Do not use tools.
Electrical Connection
Extension Cord Specifications:
Diameter .................................. 2.5 mm
2
(12 AWG)
Length...................................30 Meters (100 Feet)
Use only three-wire extension cords. Use of an
inadequate extension cord will cause the motor to stall.
Electric shock hazard:
Do not modify the plug provided
with the tool.
Connect this tool to a grounded
receptacle on a 20-amp GFCI-
protected circuit.
Failure to observe these warnings
can result in severe injury or death.
This tool must be grounded. In the event of a malfunc-
tion or breakdown, an electrical ground provides a path
of least resistance for the electric current. This path of
least resistance is intended to reduce the risk of electric
shock.
This tools electric cord has a grounding conductor and
a grounding plug as shown. Do not modify the plug.
Connect the plug to a corresponding 20-amp GFCI-
protected receptacle that is properly installed and
grounded in accordance with all national and local
codes and ordinances. Do not use an adapter.
ReceptaclePlug