11
1. Unit fails to turn on.
Hose or power connection problem.
Check the power cables for secure connection and make sure the hoses to your
pureWash Pro X2 are connected to the correct fittings, and that your cold water
faucet is turned on.
2. Red light.
Oxidizing Module has failed.
Contact your dealer or visit www.greentechenv.com/contact-us for a repair.
3. Simultaneous Flashing Blue Light and Sounding Alarm.
Power Supply Has Failed.
Contact your dealer or or visit www.greentechenv.com for a replacement.
4. No Ozone Smell in Laundry.
Check the viewing glass for bubbles as it may be producing ozone but not
injecting it into the water correctly. If no bubbles are present, your water supply
hose may be restricted or you may need to change the setting for the pureWash
Pro X2. Lift the your wash Pro X2 off the mounting bracket. If set to the STANDARD
setting, change to the HIGH EFFICIENCY setting and retest.
Contact your dealer or visit greentechenv.com/contact-us for a repair.
5. No Bubbles are Being Created.
Incorrect pressure before/after Venturi, Venturi is plugged, or Flow Rate Dial
is on the wrong setting.
First check for obstruction between the pureWash Pro X2 and the washer (inlet
screen to washer). Ensure house pressure at the supply valve has minimum of
40psi. If this fails to correct the problem then backflush your unit by switching the
hoses on the pureWash Pro X2 hose fittings and place the “Cold Water In” hose
into the basin or bucket to drain to clear the Venturi. Then return hoses to proper
connections. Second, set the Flow Rate Dial to the HIGH EFFICIENCY.
TROUBLESHOOTING