What to do if Growatt Inverter shows Warning 405?
- AAmber ToddSep 23, 2025
To address Warning 405 on your Growatt Inverter, check the firmware version. If the error message still exists, contact the manufacturer.

What to do if Growatt Inverter shows Warning 405?
To address Warning 405 on your Growatt Inverter, check the firmware version. If the error message still exists, contact the manufacturer.
What to do if Growatt MAC 50KTL3-X LV displays Error 300?
If your Growatt Inverter displays Error 300, start by checking the grid voltage. If the grid voltage is within the acceptable range and the error persists, contact the manufacturer for further assistance.
What to do if Growatt MAC 50KTL3-X LV displays Error 303?
If your Growatt Inverter is showing Error 303, check the PE (Protective Earth) connection to ensure it is properly connected. If the error message continues to appear, contact the manufacturer.
What to do if Growatt MAC 50KTL3-X LV Inverter shows Warning 402?
To resolve Warning 402 on your Growatt Inverter, first check if the optimizer is on. Next, verify the connection between the optimizer and the inverter to ensure it is normal.
What to do if Growatt MAC 50KTL3-X LV Inverter shows Warning 203?
If your Growatt Inverter shows Warning 203, check if the PV1 or PV2 wiring is short-circuited. If the error persists, contact the manufacturer.
How to fix Error 422 on Growatt Inverter?
To resolve Error 422 on your Growatt Inverter, restart the inverter. If the error message persists, contact the manufacturer.
How to fix Error 415 on Growatt MAC 50KTL3-X LV Inverter?
To resolve Error 415 on your Growatt Inverter, restart the inverter. If the error message persists, contact the manufacturer.
How to fix Error 416 on Growatt MAC 50KTL3-X LV Inverter?
To resolve Error 416 on your Growatt Inverter, restart the inverter. If the error message persists, contact the manufacturer.
How to fix Error 304 on Growatt Inverter?
To resolve Error 304 on your Growatt Inverter, restart the inverter. If the error message persists, contact the manufacturer.
How to fix Warning 404 on Growatt MAC 50KTL3-X LV Inverter?
To resolve Warning 404 on your Growatt Inverter, restart the inverter. If the error message persists, contact the manufacturer.
| Model | MAC 50KTL3-X LV |
|---|---|
| Max DC Input Voltage | 1100V |
| Number of DC Inputs per MPPT | 2 |
| Nominal AC Voltage | 400V |
| Total Harmonic Distortion (THDi) | <3% |
| DC Switch | Yes |
| Topology | Transformerless |
| Rated Power | 50000W |
| Max. DC Input Power | 60000W |
| Rated AC Power | 50000W |
| Max. AC Power | 55000W |
| Nominal Grid Frequency | 50/60Hz |
| Power Factor Adjustment Range | 0.8 leading - 0.8 lagging |
| Protection Class (According to IEC 62109-1) | Class I |
| Operating Temperature Range | -25°C to +60°C |
General safety guidelines and warnings before installation and operation.
Essential requirements for installing the inverter safely and effectively.
Specifies suitable environmental conditions for inverter installation.
Steps for installing the wall mount bracket for the inverter.
Instructions for physically mounting the inverter onto the wall bracket.
Detailed steps for connecting the inverter to the AC power grid.
Instructions for connecting the DC input from PV panels to the inverter.
Procedures for testing and verifying the inverter's functionality.
Describes how the inverter indicates and handles faults.
Methods for remotely monitoring inverter data via app and web.
Guide to installing and using the ShinePhone app for monitoring.
How to monitor the inverter using the ShineGPRS-X web interface.
Lists error codes, their descriptions, and troubleshooting suggestions.