I.High level setting
According to register address set parameters (professional operation).
J.Device Information
Check PV voltage/current, string voltage/current, AC voltage/current/power/frequency,
PID voltage/current, internal parameters, and detailed device detailed data information
about the device.
8.2.2 U Disk Monitoring
The local monitoring of U disk can realize the functions of software burning, fault
recording, curve analysis and real-time recording. Details are as follows:
1.Firmware Programming
Create the bconfig.txt file under the root of the U disk, write to the following content,
then insert the U disk to programming. Note the M3 program needs to be programming
at last time.
Figure 8.23
Figure 8.25
Figure 8.24
Figure 8.26
2.Fault Recording
Create a BCONFIG.txt file under the root directory of the USB flash drive, write
"down_fault", insert the USB flash drive to read the fault recording information, and
store a total of 100 fault recording information in the root directory. The latest number is
0.
3.Curve Analysis
Create the bconfig.txt file under the root of the U disk, write the following content, the
insert U disk to record I-V curve, then generates a form under the files in the root
directory.
4.Real Time Recording
Create the bconfig.txt file under the root of the U disk, write the following content,
then insert
U disk to read real time recording informationthen generates a form under the files in
the root directorythe form record's waveform is consistent with the ID of the command
setting.