47
Model
Specifications
MOD
3000TL3-
X
MOD
4000TL3-
X
MOD
5000TL3-
X
MOD
6000TL3-
X
MOD
7000TL3-
X
MOD
8000TL3-
X
Protection devices
DC reverse-polarity pro-
tection
YES
DC switch
YES
DC Surge protection
typell OPT
Insulation resistance mon-
itoring
YES
AC surge protection
typell OPT
AC short-circuit protection
YES
Grid monitoring
YES
Anti-islanding protection
YES
Residual-current monitor-
ing unit
YES
String Fuse protection
NO
String monitoring
OPT
AFCI protection
OPT
General data
Dimensions (W/ H / D) in
mm
425*387*147mm
425*387* 178mm
Weight
12.5kg
14kg
Operating temperature
range
-25°C ... +60°C (>45°CDerating)
Noise emission (typical)
<S35dB(A)
Altitude
4000m
Internal consumption at
night
1W
Topology
Transformerless
Cooling
Natural heat dissipation
Electronics protection de-
gree
IP66
Relative humidity
0-100%
DC connection
H4/MC4(OPT)
AC connection
Waterproof PG head+OT terminal or quick connect terminal
Interfaces
Display
OLED+LED
USB/RS485
YES
WIFI/GPRS/4G/RF/LAN
OPT