Do you have a question about the Growatt MOD 6000TL3-X and is the answer not in the manual?
| Model | MOD 6000TL3-X |
|---|---|
| Rated Power | 6000 W |
| Max. DC Power | 9000 W |
| Max. DC Voltage | 1100 V |
| Number of MPP Trackers | 2 |
| Max. Input Current per MPPT | 13 A |
| Max. Short Circuit Current per MPPT | 15 A |
| Nominal AC Power | 6000 W |
| Max. AC Power | 6600 W |
| Nominal Grid Frequency | 50 Hz / 60 Hz |
| Power Factor | >0.99 |
| THDi | < 3% |
| DC Switch | Yes |
| Overvoltage Category | II |
| Operating Temperature Range | -25 °C to +60 °C |
| Topology | Transformerless |
| Protection Degree | IP65 |
| AC Output Voltage | 230 V |
| Max. DC Input Voltage | 1100 V |
| Nominal AC Voltage | 230/400 V |
| AC Voltage Range | 180-280V / 310-480V |
| Protection Class | Class I |
| Cooling | Natural convection |
| Type | Grid-tied PV inverter |
Specifies qualified personnel requirements and general safety instructions for installation and operation.
Covers warnings for electrical connections, assembly, operation, and potential hazards.
Covers wall mounting, location, orientation, environmental conditions, and clearance.
Covers safety, AC side wiring, preparation, and grounding requirements.
Instructions for DC wiring, PV module selection, wire length, and DC terminal connection.
Covers AC connection steps, signal cable connection, active power control, GFCI, and DRMS.
Details inverter grounding and lightning protection measures.
Explains AFCI system, danger info, operation steps, and debugging.
Interprets error messages and lists system error codes with suggested solutions.
Step-by-step procedures for safely starting and shutting down the inverter.












Loading...