Do you have a question about the Grunaire GSU121HX and is the answer not in the manual?
Overview of the Gruniare HX series minisplit outdoor unit and its capabilities.
Details key features like DC Inverter, R410a refrigerant, and operating temperature ranges.
Information on flare type interconnecting tubing and appendix references.
Notes that each indoor unit comes with its own installation and operation manuals.
Detailed specifications for DC Inverter 1:1 outdoor units including capacity, SEER, and dimensions.
Technical specifications for DC Inverter 1:2 outdoor units, covering various operational parameters.
Detailed specifications for the HXS-25V9A-A21A indoor unit, including fan and evaporator data.
Detailed specifications for the HXS-32V9A-A21A indoor unit, covering fan and evaporator components.
Specifications for the HXS-25V9A-A27A indoor unit, detailing fan motor and evaporator characteristics.
Specifications for the HXS-32V9A-A27A indoor unit, including fan motor and evaporator details.
Specifications for the HXS-25V9A-A48A indoor unit, covering fan motor and evaporator data.
Specifications for the HXS-32V9A-A48A indoor unit, detailing fan motor and evaporator components.
Specifications for the HX-V25G9A/A30 indoor unit, including fan motor and evaporator data.
Specifications for the HX-V32G9A/H30 indoor unit, detailing fan motor and evaporator characteristics.
Specifications for the HX-V25G9A/A46 indoor unit, covering fan motor and evaporator details.
Specifications for the HX-V32G9A/H46 indoor unit, detailing fan motor and evaporator components.
Specifications for the HX-V25G9A/A77 indoor unit, including fan motor and evaporator data.
Specifications for the HX-V32G9A/H77 indoor unit, detailing fan motor and evaporator characteristics.
Specifications for the HX-V25G9A/A79 indoor unit, covering fan motor and evaporator details.
Specifications for the HX-V32G9A/H79 indoor unit, detailing fan motor and evaporator components.
Defines the upper and lower operating limits for cooling and heating modes, and voltage requirements.
Provides dimensional drawings for the GSU091HX outdoor unit.
Provides dimensional drawings for the GSU121HX outdoor unit.
Provides dimensional drawings for the GSU181HX outdoor unit.
Provides dimensional drawings for the GSU241HX outdoor unit.
Provides dimensional drawings for the HX-50V9A-S outdoor unit.
Provides dimensional drawings for the HX-V64T9AD outdoor unit.
Provides dimensional drawings for the HX-V64WC9A outdoor unit.
Presents cooling and heating capacity data for 9000BTU indoor units across various conditions.
Graphical representation of cooling capacity correction factors based on outdoor temperature.
Presents cooling and heating capacity data for 12000BTU indoor units under different conditions.
Presents cooling and heating capacity data for 18000BTU indoor units across various conditions.
Presents cooling and heating capacity data for 24000BTU indoor units under different conditions.
Shows how tubing length affects cooling and heating capacity ratios.
Illustrates suction pressure variations with outdoor temperature for cooling mode.
Illustrates discharge pressure variations with outdoor temperature for cooling mode.
Details power supply, current ratings, circuit breaker, and wiring for GSU outdoor units.
Details power supply, current ratings, circuit breaker, and wiring for HX outdoor units.
Wiring diagrams for GSU091HX and GSU121HX outdoor units.
Wiring diagrams for GSU181HX and GSU241HX outdoor units.
Wiring diagram for the HX-50V9A-S outdoor unit.
Wiring diagrams for HX-V64WC9A and HX-V64T9AD outdoor units.
Wiring diagrams showing connections between GSI series indoor and outdoor units.
Wiring diagrams showing connections between GSU series indoor and outdoor units.
Refrigeration circuit diagram for the GSU091HX model.
Refrigeration circuit diagram for the GSU121HX model.
Refrigeration circuit diagrams for GSU181HX and GSU241HX models.
Refrigeration circuit diagram for the HX-50V9A-S model.
Refrigeration circuit diagrams for HX-V64WC9A and HX-V64T9AD models.
Details on connecting refrigerant tubing and required tightening torques for various sizes.
Introduction to the control system and details on the main PCB board functions.
Describes cooling, dehumidify, heating, auto, and ventilation modes for indoor units.
Details on setting timers for operation and sleep mode functions.
Explains air flow control via flap adjustment and turbo function operation.
Covers various protection mechanisms like frost prevention, overheat, and faults.
Includes other functions like sound indication and emergency key operation.
Details on how indoor and outdoor unit faults are displayed.
Describes test model conditions for cooling mode, specifying compressor settings.
Describes test model conditions for heating mode, specifying compressor settings.
Diagram illustrating the overall system frame and component connections.
Key performance indicators including voltage, power, frequency conversion, and environment.
Details on signals and communication handled by the outdoor unit controller.
Control logic for expansion valve, compressor frequency, and fan motor in cooling mode.
Operational logic for dehumidify and heating modes, including fan motor and reverse valve control.
Details on defrost start/end conditions, interval timing, and process sequence.
Explains oil return cycle and outdoor unit operation mode control based on indoor unit requests.
Covers various protection mechanisms for compressor and system components.
Lists common failures (F1-F8, P2-P8) and their corresponding corrective actions and troubleshooting steps.
Exploded view and parts list for the GSU091HX outdoor unit.
Exploded view and parts list for the GSU121HX outdoor unit.
Exploded view and parts list for the GSU181HX outdoor unit.
Exploded view and parts list for the GSU241HX outdoor unit.
Exploded view and parts list for the HX-50V9A-S outdoor unit.
Exploded view and parts list for the HX-V64T9AD outdoor unit.
| Refrigerant | R410A |
|---|---|
| Net Weight (Outdoor) | 30 kg |
| Category | Split System Air Conditioner |
| Cooling Capacity | 12000 BTU/h |
| Power Supply | 220-240V, 50Hz |
| Operating Temperature (Cooling) | 18°C to 43°C |