Table A: Maximum water temperature
Ambient temperature
+104 °F
(+40 °C)
+120 °F
(+48 °C)
+140 °F
(+60 °C)
+160 °F
(+71 °C)
+175 °F
(+79 °C)
Water temperature
All UP*
+230 °F
(+110 °C)
+220 °F
(+104 °C)
+210 °F
(+98 °C)
+190 °F
(+87 °C)
+175 °F
(+79 °C)
* Exceptions below:
UPS 15-35
+165 °F
(+73 °C)
+140 °F
(+60 °C)
---
UP 15-100F
+205 °F
(+96 °C)
+195 °F
(90 °C)
(+185 °F)
(+85 °C)
+175 °F
(+79 °C)
-
UP 26-120U
+205 °F
(+96 °C)
+195 °F
(90 °C)
(+185 °F)
(+85 °C)
+175 °F
(+79 °C)
-
UP 26-116
+150 °F
(+65 °C)
+140 °F
(+60 °C)
-- -
Table B: Minimum required inlet pressure
Water temperature
230 °F
(110 °C)
190 °F
(88 °C)
140 °F
(60 °C)
Inlet pressure in feet (m)
36 ft
(1.10 m)
9 ft
(2.8 m)
3 ft
(0.9 m)
Inlet pressure in psi (bar)
15.6 psi
(1.07 bar)
4.0 psi
(0.27 bar)
1.3 psi
(0.08 bar)

Related product manuals