EasyManua.ls Logo

GSi pinnacle User Manual

GSi pinnacle
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PINNACLE
CANISTER STOVE
A
C
B
D
E
Read and un derstand t his entire instr uction manual b efore using th is stove. Keep t his
instru ction manual for f uture refe rence. Prac tice using this s tove before h eading out
on your tri p to familiarize you rself with it s function and d angers. If yo u do not
unders tand this manual o r have any quest ions, please call G SI Outdoors , Inc. at
1-800-704-4474, +1- 509-928-9611, email us at info@ gsioutdoors.com or visit
our websit e at www.gsioutdoors.com.
Do not at tempt to use this s tove: (1) bef ore reading an d fully underst anding this
instru ction manual; ( 2) if you are no t prepared or c omfortabl e attending t o a burning
and/or h ot stove at all tim es; (3) if y ou observe, s mell or hear leaki ng fuel; or (4 ) if you
obser ve any conditio n with the sto ve system or in t he surroundin g environment t hat
would make o peration of an o pen flamed dev ice dangerous . Failure to follow t hese
directio ns can cause an un safe situati on leading to fire o r an explosion, re sulting in
serious b odily injury or de ath.
WARNING
Do not use s tove if part s are missing or bro ken, or with rep lacement par ts not speci fic
to your sto ve model. Use of s tove with mis sing or broken par ts, or with r eplacement
parts n ot specific to y our stove mod el, can result in bur ns severe injur y or death.
Do not at tempt to modif y or use this sto ve in any way for an y purpose oth er than
describ ed in this instr uction manual
IMPORTANT
This stov e is designed for O UTDOOR USE O NLY for boiling wate r and cooking fo od.
Use of sto ve within any enc losed space, o r for a purpose o ther than boiling w ater or
cooking f ood can cause f ire, explosion or p oisoning resul ting in serious bo dily injury
or death . You are responsibl e for your own sa fety and the s afety of tho se around you.
This manua l is not intended t o replace your go od judgment. I f you have any que stions
or concer ns contact G SI Outdoors , Inc. at 1-800-704-4474, +1- 509-928-9611, email
us at info@ gsioutdoors.com or visit our web site at www.gsioutdoors.com .
SAFETY INFORMATION
IF YOU SME LL GAS:
1/ Do not at tempt to light ap pliance.
2/ Ex tinguish any ope n flame.
3/ Discon nect from fu el supply.
Do not sto re or use gasoline or o ther liquids wit h flammable vap ours in the vicini ty of
this or any ot her appliance.
FOR YOUR SAFETY
PARTS:
a: Pot Sup ports b: B urner Head c: Va lve Body d: F lame Adjuster Val ve
e: Flame A djuster
Nominal H eat
Input Ra te:
8,768 BT U/h.
2.59 kW
187 g /h.
(51C L392 1-2010 )
200 9/142/ EC
Nominal H eat
Input Ra te:
0359-16
Cleara nce to combu stibles : top 4 ft . (1.2 m) , sides 4 f t. (1.2 m )
*Nominal H eat Input Ra te varies de pending on t est proce dures of the p articular s tandard s agency.
IGNITION HAZARD
This stov e can easily ignit e surrounding m aterials and fla mmable liquids or va pors.
Keep sto ve and cartr idge away from o ther heat sou rces. If you de termine that a
windscr een is needed us e ONLY the GSI O utdoors Pinn acle Windscr eens that are
designed f or exclusive use w ith the GSI Out doors Pinna cle Stoves in the ir prescribe d
fashion.
INJURY HAZARD
Never let c hildren use this st ove. Super vise children in th e cooking area a t all times,
keeping th em at least 10 feet ( 3+ meter s) away from t he stove.
DANGER
This stov e uses a liquid pres surized gas ( LPG) car tridge tha t is highly flammabl e and
explosi ve. Use only GSI Ou tdoors isoB utane Fuel Ca rtridges of I sobutane an d
Propan e mix (4 oz./110 g or 8 oz. /230 g) . Because GS I Outdoors c annot assure t he
quality an d safety of o ther manufac turers’ fuel c artridge s, do not attem pt to fit other
type s or makes of gas car tridges to t he Pinnacle Sto ve. Follow this s afety
informa tion when using G SI cartridg es:
!/ Listen an d smell for leakin g gas. Leaking g as is a serious haz ard. Natural L PG is
invisible an d odorless; s trong odor ant additives h ave been adde d to the fuel mix
but can fa de over time. Le aks are not alway s detectab le by smell. Do not use t his
stove if i t is leaking, dama ged, or does not o perate prop erly.
!/ Check th at the stove an d fuel cartr idge connec tion is secure and t ight. If the
connec tion does not loo k or feel secure, o r if you hear or smell l eaking gas, do no t
use stov e or cartridg e. Move stove t o a well-ventila ted area away f rom any
ignition so urce to locat e and stop the le ak. Only check f or leaks outdo ors using
soapy wa ter. Bubbles will for m if the soapy w ater is poured o ver a leak. Do not t ry
to detec t leaks using a flam e.
GENERAL FUEL CARTRIDGE SAFETY
This appliance can produce carbon monoxide
which has no odor.
Using it in a n enclosed spa ce can kill you.
Never us e this stove in a n enclosed spa ce such as
a camper, t ent, car or ho me.
DANGER
CARBON MONOXIDE HAZARD
LIMI TED WARR ANTY/ LIMITAT IONS OF REM EDIES AND L IABIL ITY
USA, Ca nada and other a pplicable Coun tries
Limit ed Warrant y :
GSI Outdo ors, Inc. USA ( GSI Outdoo rs) to the orig inal owner (“O wner”) , under
intende d use and mainten ance, warran ts the enclos ed product ( “Product ”) to be free
from def ects in mater ials and workma nship for the life o f the Produc t. No warrant y
against de fects in mate rials and work manship will apply i f Product is ( i) altered in any
way, (ii) us ed for purpos es inconsiste nt with Produ ct’s intended p urpose or des ign, or
(iii) impr operly maint ained. Warran ty will furt hermore be voi ded where Ow ner/user
(i) faile d to follow Produ ct instruc tions or warnin gs or (ii) subjec ted Produc t to misuse,
abuse, or ne glect.
During th e warranty p eriod, original p roduct par ts determin ed by GSI Outdo ors, Inc.
to be defe ctive in mater ials or workma nship will be repair ed or replaced a s Owner’s
sole reme dy. GSI Outdoor s, Inc. reser ves the right t o replace any dis continued
produc t with a new prod uct of compar able value and fun ction. A retu rned Produc t
deemed ir reparable be comes the pro perty of G SI Outdoors, I nc. and will not be
returned.
EXCLU DING THE LIMI TED WARRA NTY PRO VIDED ABO VE, GSI OUT DOORS, INC., I TS
AFFL IIATES AND T HEIR SUPPL IERS, TO THE M AXIMU M EXTEN T PERMIT TED BY
LAW, MAK E NO WARRAN TIES, EXP RESSED OR IM PLIED, AND DI SCLAIM A LL
WARRA NTIES, DUT IES AND COND ITIONS, WH ETHER E XPRESSE D, IMPLIED OR
STATUTO RY, WITH RESP ECT TO THE PR ODUCT, INCLUDI NG WITHOU T LIMITATION
WARRANTY
!/ Only chan ge the cartr idge outside an d at least 25 fee t (7.6 meters) fr om people and
any sourc e of ignition.
!/ Always p osition stov e on a stable, solid l evel surfac e before using s tove. Check
and if nece ssary clea n the seals for dus t, proper sea ting or any wear b efore
connec ting a new fuel car tridge to th e stove. Do not u se stove if seal s are
damaged or worn.
!/ Keep sto ve and fuel car tridge at leas t 25 feet (7.6 meter s) away fro m other heat
source s. If you expos e the fuel car tridge to high he at, the cart ridge will explo de or
leak resul ting in serious b odily injury or de ath. This sto ve can ignite com bustible
material s, flammable liquid s and vapors cre ating a situat ion where fire, b urns
severe inj ury or death c an result.
!/ Follow all wa rnings on fuel ca rtridges r egarding use an d storage.
GENERAL FUEL CARTRIDGE SAFETY
ANY IMPLIED WARRANTIES OF MERCHANTABILITY, AGINAST LATENT DEFECTS,
FITNE SS FOR A PART ICULAR P URPOSE, O R CORRESPO NDENCE TO DES CRIPTIO N.
Warrant y Service . To obtain servi ce under this war ranty, the war ranty- eligible
Produc t must be pres ented to GSI Out doors, Inc. b y calling 1-800 -704-4 474 [M-F,
8:0 0-4:3 0, PDT] or emaili ng info@ gsioutdoor s.com.
Owner is r esponsible for a ll costs assoc iated with re turning Pro duct to GSI Out doors
for ser vice. Where a t its sole discre tion GSI Outdo ors deems Pro duct eligible for
warran ty repair or re placement, G SI Outdoors w ill pay the shippin g and handling
associa ted with ret urning repaire d or replaced P roduct to Ow ner. In instance s where
GSI Outdo ors deems a ret urned produ ct ineligible for w arranty se rvice, GSI Ou tdoors
will, if possi ble, repair prod ucts for a rea sonable charg e that includes r eturn shippin g
and handlin g. For warran ty return s ervice det ails, please go to
www.gsioutdoors.com.
Limitat ion of Remedies . Should a court o f competent ju risdiction fin d the limited
warran ty set fort h above breac hed, GSI Outdo ors’ only obliga tion will be to, at it s
option, ei ther repair or re place Produ ct. Should the a forementio ned remedy fail o f its
essent ial purpose, GS I Outdoors will, in e xchange for re turn of Prod uct, refund t o
Owner P roduct’s origin al purchase pr ice. THE FOR EGOING REME DY IS THE SOLE
AND EXC LUSIVE RE MEDY OF THE PU RCHASER A GAINST GSI O UTDOORS, I TS
AFFI LITAES AND T HEIR SUPPL IERS, REGA RDLES OF LE GAL THEO RY.
Limitat ion of Liability. GS I Outdoors’, its a ffiliates’ an d their suppliers’ m aximum
WARRANTY WARRANTY
liability is lim ited to inciden tal damages no t to exceed the o riginal purcha se price of
the Prod uct. GSI OUT DOORS, IT S AFFILI TATES AND THEIR S UPPLIER S HEREBY
DISCL AIM AND EX LUDE ANY RE ASON WHAT SOVER. TH IS EXCLUSI ON AND
LIMITATI ON APPLIE S TO ALL LEG AL THEORIE S UNDER WHIC H DAMAGES M AY BE
SOUGHT, AN D WILL APP LY EVEN IF ANY R EMEDY FAIL S OF ITS ESSEN ITAL
PURPOSE.
This limite d warranty g ives Owner s pecific legal r ights; Own ers may have ad ditional
rights, w hich may vary s tate to sta te.
Always c ompletely foll ow safety, use o peration, and m aintenance in struction s for
this or any ot her GSI Outdo ors product .
Europe an Union custome r statutor y rights are n ot affect ed.
GSI Outdoors, Inc.
For prod uct servic e and informat ion contact
GSI Outdoors, Inc. USA
1023 S. Pine s Road, Spokan e WA. 99206 U SA
1-800-704-4474 or 509-928-9611
www.gsioutdoors.com
KNOW YOUR STOVE BEFORE YOU GO!
Familiariz e yourself wit h the parts o f your GSI Outdo ors Pinnacle C anister Stov e and
the inst ructions for u se and storage b efore conne cting the sto ve to its fuel ca rtridge.
Never use t his stove in any ot her way than is de scribed in th e following inst ructions.
For more in formation or v ideos on how to us e the GSI Outdo ors Pinnacle C anister
Stove vis it our website at w ww.gsiout doors.com
#56 002: Pinnacle
®
Canister Stove
© 2015 GSI Outdoors, Inc.
1023 S Pines Rd Spokane WA 99206 USA
PO Box 132 Wakefield, England WF1 1XJ
Question and Answer IconNeed help?

Do you have a question about the GSi pinnacle and is the answer not in the manual?

GSi pinnacle Specifications

General IconGeneral
BrandGSi
Modelpinnacle
CategoryStove
LanguageEnglish

Summary

Know Your Stove Before You Go!

General Safety Information

Essential safety guidelines and precautions for using the canister stove.

Carbon Monoxide Hazard

Critical information on the dangers of carbon monoxide produced by the stove.

Fuel Cartridge Safety

Guidelines for the safe handling and use of fuel cartridges with the stove.

Warranty Information

Warranty Details

Details regarding the product's limited warranty and disclaimers.

Operating Instructions

Connecting Stove and Cartridge

Steps to safely connect the canister stove to the fuel cartridge.

Setting Up the Stove

Instructions for properly setting up the canister stove before use.

Lighting the Stove

Procedure for safely igniting the canister stove.

Using the Stove for Cooking

Guidance on how to use the stove for cooking purposes.

Turning Off the Stove

Steps for safely extinguishing and turning off the canister stove.