13
3. Control of the electrical state of the product
Check electrical functions and signals.
Check the wiring for faults and defects.
Check the cable bushings.
Check connection options, connectors, etc.
Check the seal on the control box.
4. Control of the mechanical state of the product
Clean dirt and other impurities from the product.
Inspect and assess vital parts of the product.
Replace any parts of the product which are defective or worn.
Lubricate the product.
5. Go through point 2 again, to check that everything works
6. Did any new problems arise/were new problems noted in point 5?
If new problems arose, go back to point 2.
If no new problems were noted, conclude the inspection.
5.04 Trouble Shooting
1. Is the plug from the mains network in the socket?
Put the plug in the socket.
2. Is the socket switched on?
Switch the socket on.
3. Is there power in the socket, the fuse may have blown?
Check the fuses and change the fuse if necessary.
4. Is the emergency stop activated?
The emergency stop is released by turning the switch until it springs up.
5. Can the lifting platform mounted with safety nosing list go up but not down?
Clean any impurities from the safety nosing strip.
Check the safety nosing strip for other blockages.
6. Are the connecting plugs between the source of power and the lifting platform
connected?
Connect the plugs.
7. Is the platform overloaded?
Remove some of the load from the lifting platform.
Observe the maximum load indication of the platform.
If the above points do not solve the problem, please contact the Guldmann
Service Team.