APPROXIMATE GREASING INTERVALS FOR
GUSHER PUMPS
52VHD POWER FRAME
TEMP. DEG. F. 1725 R.P.M. 3450 R.P.M.
150 DEG. 5760 HRS. 2880 HRS.
175 DEG. 2880 HRS. 1440 HRS.
200 DEG. 1440 HRS. 720 HRS.
225 DEG. 720 HRS. 360 HRS.
53VHD POWER FRAME
TEMP. DEG. F. 1725 R.P.M. 3450 R.P.M.
150 DEG. 5760 HRS. 2880 HRS.
175 DEG. 2880 HRS. 1440 HRS.
200 DEG. 1440 HRS. 720 HRS.
225 DEG. 720 HRS. 360 HRS.
54 VHD POWER FRAME
TEMP. DEG. F. 1725 R.P.M. 3450 R.P.M.
150 DEG. 3840 HRS. 1920 HRS.
175 DEG. 1920 HRS. 960 HRS.
200 DEG. 960 HRS. 480 HRS.
225 DEG. 480 HRS. 240 HRS.
*USE CHEVRON SRI #2 OR SHELL DOLIUM ‘R’ BALL BEARING GREASE OR EQUIVILENT.
REMOVE ALL OLD GREASE ONCE A YEAR AND CLEAN BALL BEARINGS AND BALL
BEARING HOUSING WITH KEROSENE OR CARBON TETRACHLORIDE BECAUSE OF
OXIDATION AND HARDENING OF THE GREASE OVER LONG PERIODS OF TIME.
*THIS IS AN APPROXIMATE LUBRICATION CHART FOR STANDARD PUMP OPERATION.
CONSULT THE FACTORY FOR ANY ADVERSE OPERATION.
!WARNING!
DO NOT LUBRICATE WHILE SHAFT IS IN MOTION.
DO NOT OVERGREASE.