Questions and Answers

  • G
    Glenda MorrisAug 15, 2025
    What to do if the GUSMER H-3500 Construction Equipment primary heater heats, but the red light on the Primary Heater Controller is continuously ON?
    • J
      Jonathan MillsAug 15, 2025
      An over-temperature safety circuit with four thermal limit safety switches is attached to the heating tubes. If the tube surface temperature exceeds 230° F, the thermal limit safety switch will automatically trip the primary heater circuit breaker to OFF. Allow the Primary Heater to cool down before resetting the circuit breaker. Do not attempt to reset the circuit breaker more than once; determine and correct the problem's cause first.
  • M
    Morgan GibsonAug 18, 2025
    What to do if the GUSMER H-3500 hose or hoses adjacent to the unit are warm but hoses downstream are cold?
    • H
      handersonAug 18, 2025
      The Hose Heat Solid State Relay (SSR) needs proper heat dissipation via the heat sink. Ensure the heat sink isn't obstructed by rags or coverings and that the unit has adequate air circulation. With power OFF, remove the lead from terminal #1 on the SSR and check for continuity across terminals #1 and #2. If continuity exists, the SSR is shorted and must be replaced.
  • K
    Kenneth WilliamsAug 22, 2025
    What to do if the GUSMER H-3500 hose does not heat, and the amber light on the Hose Heater Controller is ON?
    • D
      Daniel RamseyAug 22, 2025
      Adjust the hose heater power set clockwise to achieve maximum amperage.
  • R
    Raymond WilsonAug 26, 2025
    What to do if the GUSMER H-3500 Construction Equipment primary heater does not heat, and the amber light on the Primary Heater Controller is ON?
    • M
      Mr. Scott Erickson IIAug 26, 2025
      The primary heating circuit is protected by two 30 Amp fuses. With power OFF, remove the fuse(s) and check for continuity, or replace it with a fuse known to be good.
  • J
    Julian ConleyAug 28, 2025
    What to do if the GUSMER H-3500 hose does not heat, and the red light on the Hose Heater Controller is ON?
    • L
      Luis RhodesAug 28, 2025
      With the power OFF, remove the inline fuse and check it for continuity. Replace the fuse if needed.
  • S
    Sarah JacobsAug 31, 2025
    What to do if the GUSMER Construction Equipment primary heater does not heat, and the red light on the Primary Heater Controller is ON?
    • D
      David CohenSep 1, 2025
      With the Main Power OFF, remove the lead from terminal #1 on the Primary Heater SSR. Check for continuity across terminals #1 and #2. If there is continuity, the SSR has shorted closed and needs to be replaced.
  • K
    Kaitlyn WilsonSep 4, 2025
    Why does the GUSMER Construction Equipment hose warm but not reach temperature or take too long?
    • L
      Laura Wilcox DDSSep 4, 2025
      The H-2000/H-3500 hose heater operates effectively with up to 310 feet of hose. At 310 feet, the hose temperature should increase by approximately 120° F in 40 minutes. Using hose lengths exceeding 310 feet will reduce its heating capability.
  • M
    Mr. Anthony VazquezSep 7, 2025
    What to do if GUSMER H-3500 Construction Equipment primary heater partially heats but the amber light on the Primary Heater Controller is ON continuously?
    • S
      Stephanie PhillipsSep 7, 2025
      The three heat controller units on the H2000/H-3500 are interchangeable. To check if a control unit works, power OFF, and replace the controller in question with one that is known to be functional.
  • A
    angela92Sep 12, 2025
    What to do if the GUSMER H-3500 hose does not cycle automatically, and the red light on the Hose Heater Controller is ON?
    • A
      amberrodriguezSep 12, 2025
      The three heat control units on the H-2000/H-3500 are directly interchangeable. To check if the control unit is working correctly, switch OFF the power, and swap the suspected control with one known to be in good working order.