Questions and Answers

  • W
    William CarterAug 14, 2025
    What to do if the GUSMER H-2000 Construction Equipment primary heater heats, but the red light on the Primary Heater Controller is continuously ON?
    • P
      Patricia HatfieldAug 14, 2025
      An over-temperature safety circuit with four thermal limit safety switches is attached to the heating tubes. If the tube surface temperature exceeds 230° F, the thermal limit safety switch will automatically trip the primary heater circuit breaker to OFF. Allow the Primary Heater to cool down before resetting the circuit breaker. Do not attempt to reset the circuit breaker more than once; determine and correct the problem's cause first.
  • K
    Kimberly ArnoldAug 18, 2025
    What to do if the GUSMER H-2000 hose or hoses adjacent to the unit are warm but hoses downstream are cold?
    • B
      barbarathompsonAug 18, 2025
      The Hose Heat Solid State Relay (SSR) needs proper heat dissipation via the heat sink. Ensure the heat sink isn't obstructed by rags or coverings and that the unit has adequate air circulation. With power OFF, remove the lead from terminal #1 on the SSR and check for continuity across terminals #1 and #2. If continuity exists, the SSR is shorted and must be replaced.
  • H
    Harold JohnsonAug 21, 2025
    What to do if the GUSMER H-2000 hose does not heat, and the amber light on the Hose Heater Controller is ON?
    • J
      jasminryanAug 21, 2025
      Adjust the hose heater power set clockwise to achieve maximum amperage.
  • G
    George HoweAug 25, 2025
    What to do if the GUSMER H-2000 primary heater does not heat, and the amber light on the Primary Heater Controller is ON?
    • A
      Alan GarciaAug 25, 2025
      The primary heating circuit is protected by two 30 Amp fuses. With power OFF, remove the fuse(s) and check for continuity, or replace it with a fuse known to be good.
  • J
    Jessica CantrellAug 28, 2025
    What to do if the GUSMER Construction Equipment hose does not heat, and the red light on the Hose Heater Controller is ON?
    • G
      gregorytaylorAug 28, 2025
      With the power OFF, remove the inline fuse and check it for continuity. Replace the fuse if needed.
  • E
    Ethan BennettAug 31, 2025
    What to do if the GUSMER H-2000 primary heater does not heat, and the red light on the Primary Heater Controller is ON?
    • J
      Jessica GravesAug 31, 2025
      With the Main Power OFF, remove the lead from terminal #1 on the Primary Heater SSR. Check for continuity across terminals #1 and #2. If there is continuity, the SSR has shorted closed and needs to be replaced.
  • J
    jason09Sep 3, 2025
    Why does the GUSMER H-2000 Construction Equipment hose warm but not reach temperature or take too long?
    • S
      samuel90Sep 4, 2025
      The H-2000/H-3500 hose heater operates effectively with up to 310 feet of hose. At 310 feet, the hose temperature should increase by approximately 120° F in 40 minutes. Using hose lengths exceeding 310 feet will reduce its heating capability.
  • E
    Edward LeeSep 7, 2025
    What to do if GUSMER H-2000 primary heater partially heats but the amber light on the Primary Heater Controller is ON continuously?
    • T
      Tammy MartinSep 7, 2025
      The three heat controller units on the H2000/H-3500 are interchangeable. To check if a control unit works, power OFF, and replace the controller in question with one that is known to be functional.
  • R
    Ronald WilliamsSep 12, 2025
    What to do if the GUSMER H-2000 Construction Equipment hose does not cycle automatically, and the red light on the Hose Heater Controller is ON?
    • M
      matthew28Sep 12, 2025
      The three heat control units on the H-2000/H-3500 are directly interchangeable. To check if the control unit is working correctly, switch OFF the power, and swap the suspected control with one known to be in good working order.