Electrical Safety Tester
GPT-9000 / GPT-9000A Series
USER MANUAL
GW INSTEK PART NO. 82PT-90000EF1
ISO-9001 CERTIFIED MANUFACTURER
w ww . . co m
information@itm.com1.800.561.8187

Other manuals for GW Instek GPT-9804

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPT-9804 and is the answer not in the manual?

GW Instek GPT-9804 Specifications

General IconGeneral
TypeSafety Tester
Insulation Resistance Voltage Resolution1 V
Ground Bond Resistance Resolution0.001 Ω
DisplayLCD
AC Withstand Voltage0.05 kV to 5 kV
AC Withstand Voltage Resolution1 V
DC Withstand Voltage0.05 kV - 6.00 kV
DC Withstand Voltage Resolution1 V
Insulation Resistance Voltage0.05 kV - 1.00 kV
Ground Bond Resistance Range0.001 Ω to 1 Ω
Power Source100 VAC to 240 VAC, 50/60 Hz
Output Voltage Range0.05 kV to 6 kV (DC), 0.05 kV to 5 kV (AC)
Frequency Range50 Hz / 60 Hz
Voltage Resolution1 V
InterfaceRS-232, USB
Output Voltage0.05 kV to 6 kV (DC), 0.05 kV to 5 kV (AC)
Power Supply100 VAC to 240 VAC, 50/60 Hz

Summary

Safety Instructions

Getting Started

GPT-9000/9000A Series Overview

Provides a general overview of the GPT-9000/9000A safety tester series.

Setup Procedures

Guides users through the initial setup and power-up process for the tester.

Line Voltage Connection and Power Up

Explains how to connect the tester to power and turn it on.

Workplace Precautions

Outlines essential safety precautions for the operating environment.

Operating Precautions

Lists important precautions to follow during the operation of the tester.

Operation

Test Lead Connection Procedures

Explains how to connect test leads for ACW, DCW, IR, and GB tests.

Manual Testing Setup

Covers creating, editing, and running manual tests for ACW, DCW, IR, and GB.

Edit Manual Test Settings

Explains how to modify parameters for existing manual tests.

Setting Test Voltage/Current

Details how to set the voltage or current parameters for a test.

Setting Upper and Lower Limits

Describes how to define pass/fail criteria for test results.

Running a Manual Test

Provides steps for executing a configured manual test.

Automatic Test Procedures

Covers creating, editing, and running automatic test sequences.

Edit Automatic Test Settings

Explains how to modify parameters for existing automatic tests.

Running an Automatic Test

Provides steps for executing a configured automatic test sequence.

Remote Control

Interface Configuration

Details USB, RS232, and GPIB interface setup for remote control.

Command Syntax

Explains the structure and rules for SCPI commands.

Command List

Provides a comprehensive list of available SCPI commands.

Appendix

Test Errors

Lists and explains error messages that may appear during test operation.

Product Specifications

Details the technical specifications for the GPT-9000/9000A series testers.