Mounting Instructions
46
Withdrawing access rights from all user keys
If a user key is lost and should no longer retain its access rights, the
access rights of all user keys must be withdrawn at the Door
Terminal. After this, all the keys that remain and are to have access
rights must be re-authorized/learned again.
1. Hold the red Programming DELETE Key-stick in front of the
display of the Door Terminal Basic. The red LED blinks.
2. Hold the green Programming ADD Key-stick in front of the display
of the Door Terminal Basic. The red LED lights up solid briefly.
The access rights of all the user keys have been withdrawn.
3. All those keys that are to retain access rights must be learned
again to reassign access rights.