Relocation Procedures 
Note: in case relocation is required, the joint of evaporator gas/liquid pipes of the indoor unit shall be cut off with 
a cutting knife. Connection is only allowed after re-flaring (the same to the outdoor unit).  
Maintenance Instructions 
Maintenance Precautions 
Precautions 
•  For all the faults requiring welding the refrigeration pipelines or components inside the refrigeration system 
of R32 refrigerant air conditioners, maintenance at the user’s site is never allowed.  
•  For the faults requiring radical disassembly and bending operation of the heat exchanger, such as the 
replacement of the outdoor unit chassis and integral disassembly of the condenser, inspection and maintenance at 
the user’s site are never allowed. 
•  For the faults requiring replacement of the compressor or parts & components of refrigeration system, 
maintenance at the user’s site is not allowed. 
•  For other faults not involved in the refrigerant container, internal refrigeration pipelines and refrigeration 
elements, the maintenance at the user’s site is allowed, including the cleaning and dredging of the refrigeration 
system requiring no disassembly of refrigeration elements and no welding.  
•  In case replacement of gas/liquid pipes is required during maintenance, the joint of evaporator gas/liquid 
pipes of the indoor unit shall be cut off with a cutting knife. Connection is only allowed after re-flaring (the same 
to the outdoor unit).  
Qualification Requirements of Maintenance Personnel 
1.  All the operators or the maintenance personnel involved in refrigerating circuits shall be provided with the 
effective certificate issued by an industry-accepted assessment institute, to ensure that they are qualified for safety 
disposal of refrigerant as required in the assessment regulations.  
2.  The equipment can only be maintained and repaired as per the method recommended by the manufacturer. 
In case the assistance from personnel of other disciplines is required, the assistance shall be supervised by the 
personnel with qualification certificate involved in flammable refrigerant.  
7