EasyManua.ls Logo

Haier 2U14CS1ERA - The Outdoor Fan Control (Exchange Fan)

Haier 2U14CS1ERA
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2U14CS1ERA-SM
Functions and control
24
Domestic Air Conditioner
Refrigeration/dehumidification mode::
Serial No. Temperature scope Frequency limitation
1
Twh16
Max_hz1 34HZ
2
16<Twh24
Max_hz2 40 HZ
3
24<Twh32
Max_hz3 62 HZ
4
32<Twh44
Max_hz4 68 HZ
5 Twh>44 Max_hz5 40 HZ
Remarks: the above are not only the maximum frequency limitations of the complete appliance
which are affected by the environment, but also the maximum ability limitation of the system.
When the starting ability is not the maximum, its maximum frequency limitation is calculated by
the following equations:
The frequency limitation which is affected by the temperature and under the condition of actual
ability˙the actural running system ability*the maximum frequency which is limited by the
temperature and under the condition of maximum ability/the maximum designing ability of the
system
T=ě˄Ti*Pi˅/ěPi (Ti=|Tst_i-Tnh_i the indoor environment temperature| ;Pi˙i the
ability of the indoor unit)
Refrigeration/dehumidification:
Heating mode˖
K=ěKi/the number of running machines
The calculation of the actual output frequency: when there is no healthy airflow: F =F-ED-*hPhK
When the healthy airflow has been set: F =F-ED-*hPhK˄airflow speed˅hK˄healthy airflow˅
When refrigerating, it is needed to satisfy ˢˉ˩INˉ< F<ˢˉ˩˝˴ˉ
When heating, it is needed to satisfy ˢˉ˩INˉr< F<ˢˉ˩˝˴ˉr
5.2.2˖The outdoor fan control (exchange fan)
When the fan is changed among every airflow speed (including stop blowing), in order to avoid
the airflow speed from skipping frequently, it must be kept under each mode for over 30 seconds,
and then it can be changed to another mode (when refrigerating, the time is changed to 15
T
<1
˙1 ˙2 ˙3
>=4
The percentage of
the rated frequency P
50% 70% 100% 120% 140%
T
<1
˙1 ˙2 ˙3
>=4
The percentage of the
rated frequency P
50% 70% 100% 130% 180%
The indoor set
airflow speed
Breeze Low Medium High Strong Quiet Healthy
airflow
The percentage
of the rated
frequency Ki
70ˁ
80% 90% 100% 120% 70% 70%

Other manuals for Haier 2U14CS1ERA