EasyManua.ls Logo

Haier AB09CS1ERA - Base Operation

Haier AB09CS1ERA
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-9-
>_]]VbTZR\ <Zb >_^UZdZ_^Vb
Cooling Heating
W 10000 10700
W 2940 2850
A 12.8 12.4
W/W 3.4 3.75
W 1500 1800
W 550 550
W 11000 11500
W 4000 4000
A / A 17.4 17.4
99% 99%
A
Winding resistance(at 20 )
Motor speed r/min
Motor output/input power W
Air-flows (H/M/L) m³/h
Type / Diameter mm
Face area
External mm
Package mm
W
Noise level H/M/L dB(A)
Weight Net / Shipping kg / kg
Type / Charge kg
m
Recharge g/m
Liquid mm
Gas mm
Max.Drop between IU & OU m
Max.Drop between indoor units m
Max.Piping length between IU & OU m
Max.Total length m
Item Model
5U34HS1ERA
Rating capacity
Function
Power input (indoor + outdoor)
Current input (indoor + outdoor)
EER / COP
Minimum capacity
Minimum power input
Maximum capacity
Maximum power input (indoor + outdoor)
Norminal condition: indoor temperature (cooling): 27 DB/19WB, indoor temperature (heating): 20 DB
Outdoor temperature(cooling): 35DB/24WB, outdoor temperature(heating): 7 DB/6WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound
intensity meter. It is a sound pressure noise level.
Fan motor model
Motor type
Max.Running current (indoor + outdoor)
Fuse size (recommended size) 30
Power source
Power facor(under rating power input)
Axial × 1
Max. 900
100/125
1PH, 220-230V~, 50/60Hz
Heat
exchanger
TP2M / 7.0
about 0.75
Number of rows
Fan type × Number
DC
3
2~5
EHDS80A100AS
Dimension
(WxDxH)
948/340/840
1040/430/1000
PMVsRefrigerant control method
Pipe size
5* Φ6.35
4* Φ9.52(A,B,C,D)+1*Φ12.7(E)
Defrosting method
Refrigerant
58/-/-
77/88
R410A / 3.2
20
1. The above performance data are from the combination of 5U34HS1ERA+3*AS09CS1ERA+1*AS18CS1ERA.
2. Large drop and long piping installation will obviously reduce the total capacity.
Flared
Between
IU & OU
15
7.5
25
Piping
Connecting method
80
Automatic by reversible cycle
Crankcase heater power 35
Indoor units number
Model / Manufacture
Oil charge and type
Type
Outdoor unit
Compressor
Fan system
about 4000
TNB220FLHMC-L / MGC
870CC / FV50S
Twin Rotary (DC inverter)
0.88
Total liquid piping length without recharge
less than 40

Other manuals for Haier AB09CS1ERA

Related product manuals