    Do  not  damage  any  parts  of  the  air
conditioner  that  carry  refrigerant  by
piercing or perforating the air conditioner's
tubes with sharp or pointed items, crushing
or  twisting  any  tubes,  or  scraping  the
coatings off the surfaces. If the refrigerant
spurts out and gets into eyes, it may result
in serious eye injuries.
   Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers  or  any  other  things  into  the
inlet/outlet and swing louver.
   Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
   The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following
situation
2. If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agentor a similar qualified person.
3. If the fuse on PC board is broken please
change it with the type of T 3.15A /250VAC.
Cautions
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
  27           32             18
  19           23             14
  35           43              -5
  24           26              --
  20           27             15
 14.5          --              --
   7            24            
 -15
   6            18              --
DB  C
WB  C
DB  C
WB  C
Indoor
outdoor
DB  C
WB  C
DB  C
WB  C
For  EAA  series :
For  ERA  series:
4. The wiring method should be in line with
the local wiring standard.
5. The power and connecting cable are self-
provided, For series 
122, AB182ACEAA, The
requirement of the power cable:
H05RN-F 3G 2.5mm
2  .
The requirement of connecting cable:
H05RN-F 3G 2.0mm
2 
+H05RN-F 1x0.75mm
2.
For other series, refer to outdoor operation
manual to select the power cable and
connecting cable.
6. The breaker of the air conditioner should be
all-pole switch; and the distance between its
two contacts should be no less 3mm. Such
means for disconnection must be incorporation
in the fixed wiring.
7. The waste battery shall be disposed properly.
8. The indoor unit installation height is at least
2.5m.
9. The air breaker and the power switch should
installed the conveniently reachable pleace for
user.
10.For models 
AB242AEEAA,AB242AEERA,
AB282AEEAA,AB282AEERA,
 the emergency
switch on panel is not available.
Rated Maximum Minimum
  27          32               18
  19          23               14
  35          43               10
  24          26                 6
  20          27               15
 14.5        --                 --
   7           24                -7
   6           18                 --
Cooling
Heating
Indoor
outdoor
DB  C
WB  C
DB  C
WB  C
Indoor
outdoor
DB  C
WB  C
DB  C
WB  C