10. Diagnostic information
10.1 Failure code
remote control type unit:
failure description
indoor running
lamp flash times
indoor ambient temp. sensor failure
1
indoor coil temp.sensor failure
2
outdoor ambient temp. sensor failure
or 4-way valve broken down in heating mode
3
outdoor coil temp. sensor failure
4
over-current protection failure or phase sequence fault
5
refrigerant system pressure too high or low
6
communication between indoor PCB and receiver panel failure
8
communication between indoor PCB and outdoor PCB
9
drainage failure
10
Note: For convertible type unit, drainage failure is not available.
Wired control type unit failure code: 
 
Failure description  Failure code on wired 
controller 
Indoor ambient temp. sensor abnormal  E1 
Indoor coil temp. sensor abnormal  E2 
Outdoor ambient temp. sensor abnormal  E3 
Outdoor coil temp. sensor abnormal  E4 
Over current protection  E5 
Over high or low pressure protection  E6 
Communication between panel and indoor 
abnormal 
E8 
Communication between indoor and outdoor 
abnormal 
E9 
Water pump failure  E0