106
Super Match
Item Model AD09LS1ERA
Function —— Cooling Heating
Capacity W 2500 2900
Sensible heat ratio W 0.71 /
Dehumidifying capacity 10-³xm³/h 1.0/1.5
Indoor unit
Power supply 1PH, 220-230V~, 50/60Hz
Fan
Type × Number —— centrifugal*1
Speed(H-M-L) r/min 1230/1120/1030/900±40
Fan motor output/input power W 27/64
Air-ows (H/M/L) m³/h 550/450/400
Heat exchanger
Type / Diameter mm inner grooved pipe/
¢
7.0
Row —— 3
Total area m² 0.11
Temp. scope
℃
2.0-7.0
Dimension
(LxWxH)
External mmxmmxmm 610×484×220
Package mmxmmxmm 695×536×265
Drainage pipe (material,I.D/O.D) mm PVC 20/18
Control type(Remote/Wired) Remote or Wired
Fresh air hole dimension mm none
Electricity heater kW none
Noise level(H-M-L)
Sound power level dB(A) 47/44/41
Sound pressure level dB(A) 37/34/31
Weight(Net/Shipping) kg/kg 14/19
Controller
(O-Optional,S-Standard)
Wired YR-E17(S )/YR-E16(O)
Infared YR-HD01(O)
Piping
Refrigerant Type R410A
Pipe
Liquid mm Φ6.35(1/4)
Gas mm Φ9.52(3/8)
Connecting method Flared
Norminal condition: indoor temperature (cooling): 27
℃
DB/19
℃
WB, indoor temperature (heating): 20
℃
DB
Outdoor temperature(cooling): 35
℃
DB/24
℃
WB, outdoor temperature(heating): 7
℃
DB/6
℃
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a
sound pressure noise level.