Indoor Unit
111
Super Match
Item Model AD12MS1ERA
D
/1U12BS3ERA
Function cooling heating
Capacity KW 3.50(0.9~4.5) 4.00(1~4.8)
Sensible heat ratio / /
Total power input KW 1.08(0.28~1.8) 1.08(0.28~1.8)
Max. power input W
1800 1800
EER or COP W/W 3.23 3.71
Dehumidifying capacity 10
-
³×m³/h 1.6
Power cable H05RN-F 4G 4.0mm
2
Power source N, V, Hz
1PH, 220-230V~, 50/60Hz
Running /Max.Running current A / A 4.8(1.2-8.0)/8.0 5.6(1.2-8.0)/8.0
Start Current A 3
Indoor
unit
Unit model (color) AD12MS1ERA
(
D)
Fan
Type × Number CENTRIFUGALX1
Speed(H-M-L) r/min 700/630/570
Fan motor output/ input power W 140/105
Air-ow(H-M-L) m³/h 550/460/400
ESP pa 10/30/50/70
Heat exchanger
Type / Diameter mm inner grooved pipe/φ7.0
Row 2
Total Area /
Dimension
External(L×W×H) mm×mm×mm 750/720/250
Package(L×W×H) mm×mm×mm 920/820/340
Drainage pipe (material , I.D./O.D.) mm
PVC 25/29
Controller
(O-Optional,S-Standard)
Wired YR-E14
S)/YR-E16(O)
Infrared YR-HD01(O)
Fresh air hole dimension mm 145
Electricity Heater kW NONE
Sound power Noise level (H-M-L) dB(A) 46/43/39
Sound pressure Noise level (H-M-L) dB(A) 36/33/29
Pipe
Liquid Pipe(mm)
6.35
Gas Pipe(mm)
9.52
Connecting Method
ared
Weight (Net / Shipping) kg / kg 21.8/26
cooling Pdesignc(kW): 3.5KW SEER/CLASS 6.1/A++ QCE(Annual electricity consumption for cooling)kWh: 215
heating
Average Pdesignh(-10
o
C) 2.7KW SCOP/CLASS 4.0/A+ QHE(Annual electricity consumption for heating)kWh: 1020
Warmer Pdesignh(2
o
C) 3.1KW SCOP/CLASS 4.3/A++ QHE(Annual electricity consumption for heating)kWh: 1003
Colder Pdesignh(-22
o
C) / SCOP/CLASS / QHE(Annual electricity consumption for heating)kWh: /
Tdesignh
-10
Tbivalent:-8
o
C TOL:-15
o
C Elbu:0
Max. cooling
condition
Indoor temperature
32
/23
Max. heating condition
Indoor temperature:27
o
C/-
o
C
Outdoor temperature
46
/-
Outdoor temperature:24
o
C/18
o
C
Norminal condition: indoor temperature (cooling): 27
o
CDB/19
o
CWB, indoor temperature (heating): 20
o
CDB
Outdoor temperature(cooling): 35
o
CDB/24
o
CWB, outdoor temperature(heating): 7
o
CDB/6
o
CWB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a