120
Super Match
Item Model AD24SS1ERA(N)(P)/1U24GS1ERA
Function cooling heating
Capacity KW 7.1
(
2
~
7.6
)
7.1
(
3
~
8.3
)
Sensible heat ratio 0.74 /
Total power input KW 2.19
(
0.6
~
2.6
)
1.91
(
0.6
~
2.6
)
Max. power input W
2600 2600
EER or COP W/W 3.24 3.72
Dehumidifying capacity 10
-
³×m³/h 2.5
Power cable H05RN-F 4G 6.0mm
2
Power source N, V, Hz
1PH, 220-230V~, 50/60Hz
Running /Max.Running current A / A 9.8
(
2.3-12)/12 9.2(2.3-12)/12
Start Current A 3
Indoor
unit
Unit model (color) AD24SS1ERA(N)(P)
Fan
Type × Number CENTRIFUGALX3
Speed(H-M-L) r/min 1140/1000/900
Fan motor output/ input power W 104/74
Air-ow(H-M-L) m³/h 1000/850/750
ESP pa 0/10/20/30
Heat exchanger
Type / Diameter mm inner grooved pipe/φ7.0
Row 3
Total Area m² /
Dimension
External(L×W×H) mm×mm×mm 1170/420/185
Package(L×W×H) mm×mm×mm 1365/540/270
Drainage pipe (material , I.D./O.D.) mm
PVC 25/29
Controller (O-Optional,S-Standard) Wired YR-E16(O)/YR-E17(S)
Fresh air hole dimension mm NONE
Electricity Heater kW NONE
Sound power Noise level (H-M-L) dB(A) 57
Sound pressure Noise level (H-M-L) dB(A) 39/32/29
Pipe
Liquid Pipe(mm)
9.52
Gas Pipe(mm)
15.88
Connecting Method
ared
Weight (Net / Shipping) kg / kg 24.6/30.3
cooling Pdesignc(kW): 7.1KW SEER/CLASS 5.6/A+ QCE(Annual electricity consumption for cooling)kWh: 446
heating
Average Pdesignh(-10
o
C) 5.6KW SCOP/CLASS 4.0/A+ QHE(Annual electricity consumption for heating)kWh: 2089
Warmer Pdesignh(2
o
C) 6.0KW SCOP/CLASS 4.8/A++ QHE(Annual electricity consumption for heating)kWh: 1782
Colder Pdesignh(-22
o
C) / SCOP/CLASS / QHE(Annual electricity consumption for heating)kWh: /
Tdesignh
:
-10
℃
Tbivalent:-8
o
C TOL:-15
o
C Elbu:0
Max. cooling
condition
Indoor temperature
:
32
℃
/23
℃
Max. heating condition
Indoor temperature:27
o
C/-
o
C
Outdoor temperature
:
46
℃
/-
℃
Outdoor temperature:24
o
C/18
o
C
Norminal condition: indoor temperature (cooling): 27
o
CDB/19
o
CWB, indoor temperature (heating): 20
o
CDB
Outdoor temperature(cooling): 35
o
CDB/24
o
CWB, outdoor temperature(heating): 7
o
CDB/6
o
CWB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a
sound pressure noise level.