Indoor Unit
205
Super Match
Item                                                                          Model AP60KS1ERA(S)/1U60IS2EAB(S)
Function
cooling heating
Capacity kW
15 16
Sensible heat ratio
0.74
Total power input kW
4.66 4.69
Max. power input W
6500 6500
EER or COP W/W
3.22(A) 3.41(B)
Dehumidifying capacity 10
‐
³×m³/h
5.1
Power cable
/
Power source N, V, Hz
1, 220~230, 50
Running /Max.Running current A / A
8.4/10.5 8.4/10.5
Start Current A
/
Indoor 
unit
Unit model (color)
AP60KS1ERA(S)
Fan 
Type × Number
CENTRIFUGALX1
Speed(H-M-L) r/min
460/430/400±40
Fan motor input power kW
0.20
Fan motor output power kW
0.09
Air-ow(H-M-L) m³/h
1750/1500/1350
Heat 
exchanger 
 Type / Diameter mm
inner grooved pipe/φ7.0
Total area m²
/
Row
3
Dimension
External
(
L×W×H
)
mm×mm×mm
1850×600×350 
Package
(
L×W×H
)
mm×mm×mm
 1980×660×420 
Drainage pipe  (material , I.D./O.D.) mm
/
Controller (O-Optional,S-Standard)
Wired 
YR-E17(O)  OR YR-E16A(O)
Infrared
YR-HD01(S)
Fresh air hole dimension mm
/
Electricity heater  kW
0
Sound power  Noise level       (H-M-L) dB(A)
69
Sound power  Noise level       (H-M-L) dB(A)
51/48/44
Weight (Net / Shipping) kg / kg
57/65
Piping
Refrigerant
Type / Charge g
R410A/3600
Recharge quantity g/m
45
Pipe
Liquid mm
9.52
Gas mm
19.05
Between 
I.D &O.D
MAX.Drop m
30
MAX.Piping length m
50
Norminal condition: indoor temperature (cooling): 27
℃
DB/19
℃
WB, indoor temperature (heating): 20
℃
DB 
Outdoor temperature(cooling): 35
℃
DB/24
℃
WB, outdoor temperature(heating): 7
℃
DB/6
℃
WB 
The noise level will be measured in the third octave band limited values, using a Real Time Analyser 
calibrated sound intensity meter. It is a sound pressure noise level.