Outdoor Unit
233
Super Match
Item Model 3U24GS1ERA 3U24GS1ERA(N)
Function —— Cooling Heating
Rating capacity W 6700 8000
Cooling Pdesign W 6700
Heating pdesign(-10
) W 5300
Rated power input (indoor + outdoor) W 1675 1826
Rated current input (indoor + outdoor) A 7.28 7.9
EER / COP W/W 4.0 4.38
SEER / SCOP W/W 7.0 4.0
Minimum capacity W 1500 1800
Minimum power input W 550 550
Maximum capacity W 8200 9000
Maximum power input (indoor + outdoor) W 3100 3100
Power source —— 1PH, 220-230V~, 50/60Hz
Max. running current (indoor + outdoor) A / A 13.5 13.5
Power facor(under rating power input) —— 99% 99%
Starting current 3
Fuse size (recommended size) A 25
Outdoor unit
Compressor
Model / Manufacture —— SNB172FJGMC/ MELCOM
Oil charge and type —— 600CC, FV 50S
Type —— Twin Rotary (DC inverter)
Number —— 1
Fan
Type × Number —— Axial × 1
Speed r/min High 860
Motor output/input power W 80/100
Air-ows (H/M/L) m³/h about 2500
Heat exchanger
Type / Diameter mm TP2M / 7.94
row —— 2
Face area about 0.52
Dimension
(WxDxH)
External mm 860/308/730
Package mm 1005/423/815
Refrigerant control method —— PMVs
Defrosting method —— Automatic by reversible cycle
Crankcase heater power W none
Noise level
Sound power level dB(A) 67
Sound pressure level dB(A) 54
Weight Net / Shipping kg / kg 53/56
Piping
Refrigerant
Type / Charge kg R410A / 1.9
No need to recharge m 30
GWP 2088
Recharge g/m 20
Pipe
Liquid mm 3* Φ6.35
Gas mm 3* Φ9.52
Connecting method —— Flared
Between I.D &O.D
Drop between IU & OU m ≤7.5
Piping length between IU & OU m ≤10
Total liquid piping length m ≤30
Drop between indoor units m ≤1
Max. drop between IU &OU m 15(indoor unit lower than outdoor unit)
Max. drop between IU &OU m 15 (indoor unit higher than outdoor unit)
Max. drop between indoor units m 5
Max. piping length between IU & OU m 25
Max. total length m 60
Working temperature
Cooling
-10~46
Heating
-15~24
Tdisignh
-10
Tbivalent
-7
TOL
-15
Pto
13W Psb
13W Pck
0W Poff
0W
Cooling
A
Cap/EER
6249W/3.9
Heating
A
Cap/COP
4315W/2.61 To l
Cap/COP
5106W/2.75
B
Cap/EER
4810W/7.17 B
Cap/COP
2896W/3.93 Tb
Cap/COP
4315W/2.61
C
Cap/EER
3266W/8.9 C
Cap/COP
1789W/4.47 Cd
cooling
0.25
D
Cap/EER
3614W/10.5 D
Cap/COP
1990W/6.03 Cd
heating
0.25
Max. cooling condition
Indoor temperature
32
/23
Max. heating condition
Indoor temperature
27
/-
Outdoor temperature
46
/-
Outdoor temperature
24
/18
kWh/annum 340 kWh/annum-average 1923 kWh/annum-warm
1. The above performance data are from the combination of 3U24GS1ERA+3*AS09ZS2ERA.
2. Large drop and long piping installation will obviously reduce the total capacity.