388
Super Match
AD09~24SS1ERA AD09~24SS1ERA(N)(P) AD09~24SS1ERA(N) AD12MS1ERA AD18MS1ERA
AD12MS1ERA(D) AD18MS1ERA(D) AD24MS2ERA AD24MS2ERA(D)
AD28MS2ERA(S) AD28MS2ERA(S)(D)
LED ash times
of indoor PCB
Wired
controller
display
Contents of Malfunction Possible reasons
LED4 LED3
0 1 01
Malfunction of indoor unit
ambient temperature sensor
Sensor disconected,or broken,or at wrong
position,or short circuit
0 2 02
Malfunction of indoor unit piping
temperature sensor
Sensor disconected,or brok- en,or at wrong
position,or short circuit
0 4 04 EEPROM wrong of indoor PCB
EEPROM chip disconected or broken or wrong
programmed,or PCB broken
0 7 07
Abnormal communication
between indoor and outdoor
units
Wrong connection,or the wires be disconected or
wrong adress setting of indoor unit or faulty power
supply or faulty PCB or slave unit malfunction in
MAXI system
0 8 /
Abnormal communication
between wired controller and
indoor unit
Wrong connection or wired controller broken,or
PCB faulty
0 12 0C Malfunction of drain system
Pump motor disconnected or at wrong position,or
the oat switch,disconnected
,
or at wrong
position,or the short circuit bridge disconneted
0 13 0D Zero cross sigal wrong Zero cross sigal detected wrong
0 14 0E
Indoor unit DC fan mode
operation
DC fan motor disconected, or DC fan broken or
circuit borken
Note:
1. The outdoor failure can also be indicated by the indoor unit,the checking method as follo- ws: LED4 ash times
stands for tens digit,and LED3 ash times stands for units digit, use this bidigitate gure minus 20,then will get
the outdoor error code.For example,if the outdoor error code is 15,LED4 will ash 3 times rstly,two seconds
later,LED3 will ash 5 times , and four seconds later the process will repeat again.
2. LED4 is a yellow one on the indoor PCB,LED3 is a green one.
3. To get much more details about the out door unit failure,please refer to the outdoor unit trouble shooting list.