46
Super Match
AB60CS1ERA(S)
AB24ES1ERA(S)
AB28ES1ERA(S)
AB36ES1ERA(S)
AB48ES1ERA(S)
AB60ES2ERA(S)
AB60CS1ERA(S)
1280(Ceiling opening)
(Distance between
suspending bolts)
1070
515
515
20 Over
AB09CS1ERA
AB12CS1ERA(S)
AB18CS1ERA(S)
Indoor unit Panel
PB-700IB
PB-950JB
PB-1340IB
(2) Cut an opening in ceiling for installation if necessary. (when ceiling already exists.)
■ Refer to paper pattern for dimension of ceiling hole.
■ Connect all pipings (refrigerant, water drainage), wirings (inter unit cable) to indoor unit, before installation.
■ Cut a hole in ceiling, may be a frame should be used to ensure a smooth surface and to prevent vibration.
■ Contact your real estate dealer
(3) Install a suspending bolt. (Use a M10 bolt)
■ To support the unit weight, anchor bolt shall be used in the case of already exists ceiling. For new ceiling, use
built in type bolt or parts prepared in the eld.
■ Before going on installing adjust space between ceiling.
Note:
All the above mentioned parts shall be prepared in eld.