AB71S2SG1FA
LED flash times
of indoor PCB
 
Contents of
Malfunction
Possible reasons
LED4 LED1
0
0
0
1
2
4
Malfunction of indoor
unit ambient temper-
ature sensor
Sensor disconected
,
or brok-
en,or at wrong position,or
short circuit
Malfunction of indoor
unit
piping temper-
ature sensor
EEPROM wrong of
indoor PCB
EEPROM chip disconected
or broken or wrong program-
med,or PCB broken
Abnormal communi-
cation between indo-
or and outdoor units
Wrong connection,or the
wires be disconected or wro-
ng adress setting of indoor
unit or faulty power supply
or faulty PCB or slave unit
malfunction in MAXI system
0
0
0
0
0
7
8
12
13
14
Abnormal communi-
cation between w
ired
contro
lle
r
(
or 
I.R. RECE
   
Wrong connection or wired
controller broken,or PCB
faulty
Malfunction of drain
system
,
Zero cross sigal
wrong
Zero cross sigal detected
wrong
DC Fan motor disconnected
or DC Fan broken or circuit
broken
Note:
1.The outdoor failure can also be indicated by t
h
e ind
oo
r
 
u
n
it,the checking method as follo-
ws:
If the outdoor error code is M(DECIMAL),the indoor unit’s I.R.  receiver display will sh-
 2.LED4 is a red one on the indoor PCB,LED1 is a yellow one.
 3.To get much more details about the out door unit failure,please refer to 
    the outdoor unit trouble shooting list.
 
INDOOR UNIT TROUBLE SHOOTING
Sensor disconected
,
or brok-
en,or at wrong position,or
short circuit
Pump motor disconnected
or at wrong position,or the
float switch disconnected,
or at wrong position,or the 
short circuit bridge disconne
ted
0150516957
Indoor unit DC fan
motor abnormal
I.R .
RECEIVER 
DIGITAL
DISPLAY
01
02
04
07
08
0C
0D
0E
IVER) and indoor unit
ow the after converted hexadecimal code of  “M+20“(
DECIMAL),for example,if the outdoor
error code is 2,the indoor unit I.R.  receiver display  will flash the error code 16 (2→2+20=22 
→change 
decimal 
22 to 
hexadecimal code,get 16)