110
Smart Power
1UH125&140P1ERK
CIRCUIT DIAGRAM OF OUTDOOR UNIT
0
1
2
3
SW 8
Definition
(
model
)
1UH090N1ERG
1UH105N1ERG
4
5
6
7
8
9
A
B
C
D
E
F
1UH125P1ERG
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
T
1
2
POWER  SUPPLY
TO INDOOR UNIT
Y/G
3
N
BLU
BLK
W
U
CO
M
P
RES
SOR
V
U
V
W
DRIVER
MODULE
 
CN605
FILTER&
Y/G
 1UH071N1ERG
 
L
E
D
1
L
ED
2
 power
 indicate
  communication
   indicate
T6.3A/250VAC
F
USE1
 
CN
2
DRED
CN
1
CN
14
CN10
    CN23
     
CN
21
CN
5
CN
3
CN
4
C
N6
CN
7
CN24
CN
8
CN
18
CN13
CN12
 
M
M
L
E
D
3
error&status indiate
O
N
SW6
O
N
4321
8765
CONT
ROL
B
O
A
R
D
0
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
S
W
8
S
W2
S
W3
S
W5
S
W4
MODE
UP
SET
DOWN
BLK
L
NSIG
M
E.E.V
CN19
SV1
CN17
SV2
CN20
 
CN16
 
CN9
 
 
 
RD
WHT
BLK
   
     
   
12V
GND
CN25
PWD
module
com1
C
N
15
C
N
11
module
com2
CN22
 
Crankcase 
 heater
(CHTR)
4WV
 
Tcm
 
Td
 
Te
 
Ta
 
TS
 
TH
Reserved
1UH140P1ERG
Reserved
Reserved
1UH140P1ERK
1UH125P1ERK
SW7
O
N
21
SW1-1
SW1-2
SW1-3
SW1-4
SW1-5
SW1-6
SW1-7
SW1-8
ON
OFF
Manually 
forced operation
Valid
Manually 
forced operation
invalid
Manually 
forced 
cooling
Manually 
forced 
heating
low stand
by power 
cost
normal
stand by
cost
 
unit as
air conditi-
oner 
Refrigerant
R410A
Defrost
automatic
Defrost 
by time 
Not for
base
 station 
GND
S
CN624
5V
WHT
BLK
RD
WHT
GROUND
CN608
CN603
CN602
0150516954
Y/G
SR
T
S
CN601
R
L2
L1
REACTOR
RD
DC F
AN MOT
OR 1
DC F
AN MOT
OR 2
( UPPER MOTOR )
( LOWER MOTOR)
central
control
***************************************************************
Tcm:Temperature sensor of condenser’s middle position
Ts:Compressor suction temperature sensor
Te: Defrost tempreature sensor
Tao:Outdoor unit ambient temperature sensor
Td:Compressor dischargetemperature sensor
 
Th:Temperature sensor of hot water(optional)
E.E.V:Electronic expansion valve
 LP:Low pressure switch
 HP:High pressure switch
DERD:Demand response enabling device
(Only used in
 Australia and New Zealand area 
)
***************************************************************
BLK:black   WHT:white    RD:red    Y/G:yellow/green 
Explanation of abbreviations 1:
BLU:blue  
 
4WV:Four way valve
BMS:Building Management System
2.SW6 is used for central control adress selection
refer to service manual to get more details
3.Once out of factory ,do not change the switches
 of SW1,SW6,SW7,SW8 without technical guidence.
4.Can do the parameters checking work by button 
switches SW2/SW3/SW4/SW5 and digital display
 LED 3,refer to service manual to get more details.
5.For maintenance safety  ,please operate after pow-
er supply cut off at least 3 minutes
CON1
Y/G
 
 
LP
HP
A
B
C1 C2
RD
BRN
BRN:brown
SW1
4321
8765
 
NOTE:
SW7-1
OFF
OFF
OFF
ON
ON
OFF
ON
ON
SW7-2
Definition
DERD test  selcetion 0
DERD test  selcetion 1
DERD test  selcetion 2
DERD non-test  selcetion 
  25A/500VAC
  25A/500VAC
  25A/500VAC
BLK
WHT
RD
FUSE BOARD
④Bottom  heater
 (BHTR)
⑥ water he-
ater  or hea-
ting only
③
BMS
⑤Refriger
ant R32
⑦Base
 station
application 
CENTRAL
CONTROLLER
/③BMS DEVICE
Parameters monitor
 adaptor /②
Hydro unit
①external dry contact
 input(
ON/OFF signal)
1.Dashed parts are optional.marks①②③④
⑤⑥⑦are function in future.