EasyManua.ls Logo

Haier AS25RBAHRA-PL - Outdoor DC Fan Motor Fault

Haier AS25RBAHRA-PL
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Diagnosis
33
Turn on the unit and check if
the motor can run
YES
Measure whether there is a voltage
pulse (0-15VDC) between 4 and 5 of
the CN9 terminal on the indoor PCB
The indoor motor is damaged
and need replace
NO
Is it ok?
YES
The indoor PCB is damaged
and need replace
NO