SPLIT TYPE ROOM AIR CONDITION
OPERATION MANUAL
ER
AS25TADHRA-TC
AS35TADHRA-TC
AS50TDDHRA-TC
AS25TADHRA-TH
AS35TADHRA-TH
AS50TDDHRA-TH
AS68TEDHRA-TH
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference
This appliance is filled with R32.
0011508606

Questions and Answers

  • G
    garciaheidiAug 8, 2025
    Why is my Haier AS25TADHRA-TH cooling poorly?
    • G
      George MorrisAug 8, 2025
      Several factors can cause poor cooling in your Haier Air Conditioner. Make sure that the air filter is clean; it should be cleaned every 15 days. Remove any obstacles blocking the inlet and outlet. Verify that the temperature is set correctly. Ensure all doors and windows are closed, and use curtains to block direct sunlight. Also, reduce the number of heat sources or people in the room.
  • R
    Raymond SanchezAug 12, 2025
    Why is my Haier Air Conditioner making noise?
    • N
      Nancy AdamsAug 12, 2025
      Your Haier Air Conditioner might be making noise due to several reasons. A swishing or gurgling noise, especially noticeable in the first few minutes of operation, is normal and caused by refrigerant flowing. A cracking noise during operation is also normal, resulting from the casing expanding or shrinking due to temperature changes. However, a big noise from air flow may indicate a dirty air filter, so you should clean it.
  • K
    Kelly HolmesAug 18, 2025
    Why does my Haier AS25TADHRA-TH generate smells?
    • A
      Ann LopezAug 18, 2025
      The Haier Air Conditioner may be circulating smells from the interior air, such as odors from furniture, paint, or cigarettes. To address this, ensure proper ventilation and remove any sources of odor.
  • J
    Jennifer SaundersAug 23, 2025
    What to do if my Haier Air Conditioner does not restart immediately?
    • D
      drakeblakeAug 23, 2025
      If your Haier Air Conditioner doesn't restart immediately after being stopped, this is normal. To protect the system, it won't restart until 3 minutes have elapsed. Wait for 3 minutes before restarting the unit.
  • K
    Kyle DeleonAug 28, 2025
    Why is my Haier AS25TADHRA-TH blowing out mist or steam?
    • K
      kristen75Aug 28, 2025
      If your Haier Air Conditioner blows out mist during COOL or DRY operation, it's likely due to the sudden cooling of indoor air. This is normal operation.
  • C
    Christine JacksonSep 1, 2025
    Why can't I change the fan speed in dry mode on my Haier Air Conditioner?
    • J
      Jonathan AdamsSep 1, 2025
      In DRY mode, when the room temperature becomes lower than the set temperature plus 2 degrees Celsius, the Haier unit will run intermittently at LOW speed regardless of the fan setting. This is normal operation.

Summary

Safety Warnings

General Appliance Safety

Essential precautions for safe operation and storage of the air conditioner.

Operation Guide

Indoor Unit Installation

Indoor Unit Installation Steps

Mounting and Piping

Process for mounting plate, wall hole prep, and piping connections.

Securing Unit and Cable Connections

Steps for attaching the unit and making electrical connections.

Installation Connections and Testing

Piping, Drainage, and Cable Details

Specifics on piping work, drain installation, and electrical cable connections.

Cautions and Warnings

Installation Warnings

Critical safety warnings related to installation and electrical work.

Operational Cautions

Important advice and prohibitions for safe day-to-day use of the appliance.

Troubleshooting and Specifications

Performance and Multiple Checks

Common issues, performance checks, and troubleshooting steps.

Haier AS25TADHRA-TH Specifications

General IconGeneral
BrandHaier
ModelAS25TADHRA-TH
CategoryAir Conditioner
LanguageEnglish

Related product manuals