Service diagnosis
34 Domestic air conditioner
10.3.5 IPM protection
Outdoor display: / F1 LED1 flash 2 times
Method of
IPM protection is detected by checking the compressor running condition and so on
Malfunction
Detection
Malfunction
The system leads to IPM protection due to over current
Decision
The compressor faulty leads to IPM protection
Conditions
circuit component of IPM is broken and led to IPM protection
Supposed
IPM protection dues to the compressor faulty
Causes
IPM protection dues to faulty PCB of IPM module
Compressor wiring disconnected
Troubleshooting
* Caution
Be sure to turn off power switch before connect or disconnect connector, or
else parts damage may be occurred.
NO
YES
NO
YES