Operation
Emergency operation and test operation
Base Operation
Remote controller
1
2
3
4
3
Pi
Emergency Operation:
Use this operation only when the remote controller is defective
or lost. In emergency operation the air conditioner can run
automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
the following modes:
Room
Designated Fan
Timer
Operation
temperature
temperature
mode
speed mode
Above 23
o
C
No
26
o
C AUTO COOL
Below 23
o
C
No
23
o
C AUTO HEAT
It is impossible to change the settings of temp. and fan speed,It
is also not possible to operate in timer or dry mode.
Test operation:
Test operation switch is the same as emergency switch.
Pi Pi
3.Select temp.setting
Press
button
Use this switch in the test operation when the room
temperature is below 16
o
C, do not use it in the
normal operation.
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
release
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
Air Flow Direction Adjustment
decrease rapidly
Select a desired temperature.
1.Vertical flap
Remote controller
4.Fan speed selection
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
Press FAN button. For each press, fan speed
changes as
follows:
Remote controller:
Display
circulated
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
LOW
MED HI
AUTO
(Autoswing)
(no)
2.Press button. changes as follows:
Pos.4
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
Press button again ,
vertical flap will stop over
present position,
the swing function will be cancelled
COOL/DRY/AUTO(Initial state):
HEAT(Initial state):
Operation
Remote
Mode
Note
Controller
3.Press
Under auto operation mode, the air conditioner will
automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air
conditioner automatically adjusts the fan speed according to
room temperature.
button to choose the Pos.2 and Pos.3.
AUTO
Cooling only
COOL
DRY
In DRY mode , when room temperature becomes lower
than temp.setting+2
o
C, unit will run intermittently at LOW
speed regardless of FAN setting.
HEAT
FAN
In FAN operation mode , the unit will not operate in COOL or
HEAT mode but only in
FAN mode, AUTO is not available in
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.
In HEAT mode, warm air will blow out after a short
period of the time due to cold - draft prevention function.
When FAN is set to AUTO,the air conditioner automatically
adjusts the fan speed according to room temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2. Select operation mode
COOL button:Cooling mode
HEAT button: Heating mode
DRY button: Dehumidify mode
4.Left and right air flow adjustment(manual)
Move the vertical blade by a button on airconditioner
to adjust left and right direction(This function is
unavailable on some models.)
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or at air outlet if all vertical louvers are right.
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
mode ,
otherwise, condensate water might occur.
Note:
When system is restarted by the remote controller it will
automatically memorise the previous set swing position.