EasyManua.ls Logo

Haier AS35PBPHRA-PRE - Mounting Plate Installation

Haier AS35PBPHRA-PRE
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ø60mm
G
11
EN
Indoor Unit Installation
Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is rst xed
●Fix to side bar and lintel a mounting bar, Which is separately sold,
and then fasten the plate to the xed mounting bar.
●Refer to the previous article, “ When the mounting plate is rst
xed ”, for the position of wall hole.
●Make a hole of 60 mm in diameter, slightly descending to outside
the wall.
●Install piping hole cover and seal it o󰀨 with putty after installation
[Rear piping]
●Draw pipes and the drain hose, then fasten them with the
adhesive tape.
When the mounting plate is xed side bar and lintel
Making a Hole on the Wall and Fitting the Piping Hole Cover
Wall hole
Thickness of wall
Indoor side
Outdoor side
(Section of wall hole) Piping hole pipe
Installation of the Indoor Unit
Drawing of pipe
[ Left
Left-rear piping]
●In case of left side piping, cut away, with a nipper, the lid for left
piping.
●In case of left-rear piping, bend the pipes according to the piping
direction to the mark of hole for left-rear piping which is marked on
heat insulation materials.
1.Insert the drain hose into the dent of heat insulation materials of
indoor unit.
2.Insert the indoor/outdoor electric cable from backside of indoor
unit, and pull it out on the front side, then connect them.
3.Coat the aring seal face with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials closely,
and make sure xing with adhesive tape.
●Indoor/outdoor electric cable and drain hose must be bound with
refrigerant piping by protecting tape.
[ Other direction piping ]
●Cut away, with a nipper, the lid for piping according to the piping
direction and then bend the pipe according to the position of wall
hole. When bending, be careful not to crash pipes.
●Connect beforehand the indoor/outdoor electric cable, and then
pull out the connected to the heat insulation of connecting part
specially.
●Hang surely the unit body onto the upper
notches of the mounting plate. Move the
body from side to side to verify its secure
xing.
●In order to x the body onto the
mounting plate, hold up the body aslant
from the underside and then put it down
perpendicularly
●When you unload the indoor unit, please use your hand to arise
the body to leave agra󰀨e, then lift the bottom of the body outward
slightly and lift the unit aslant until it leaves the mounting plate.
●Remove terminal cover at right bottom corner of
indoor unit, then take o󰀨 wiring cover by removing
its screws.
mounting plate
Lid for right
piping
Lid for under
piping pipe
Fix with adhesive tape
Lid for left
piping
Heat insulation
material
Indoor/outdoor
electric cable
Piping
Pipe
supporting
plate
Drain hose
Fixing the indoor unit body
Unloading of indoor unit body
Removing the wiring cover
4
Connecting the indoor/outdoor Electric Cable
agra󰀨e
mounting plate
3
2
1
B=
Ø
60mm B=
Ø
60mm
35P
A=183.5mm C=113mm
B=
Ø
60mm
B=
Ø
60mm
B=
Ø
60mm
B=
Ø
60mm
A=222mm C=165mm
36mm
43.4mm
43.4mm
42mm
40P
50P
70P
B=
Ø
60mm
B=
Ø
60mm
A=195mm
C=126mm
41mm
41mm
A=210mm
C=170mm
D=31mm
D=38mm
AS25PBPHRA*
AS35PBPHRA*
AS25RBAHRA*
AS35RBAHRA*
AS25PBAHRA*
AS35PBAHRA*
AS25PCHHRA*
AS35PCHHRA*
AS50RCBHRA*
AS50PDHHRA*
AS50PDPHRA*
AS68RDAHRA*
AS50PDAHRA*
AS71PDAHRA*
AS50RDAHRA*
AS71PEPHRA*
1.Carry out, based on the neighboring pillars or lintels, a proper
leveling for the plate to be xed against the wall, then temporarily
fasten the plate with one steel nail.
2.Make sure once more the proper level of the plate, by hanging a
thread with a weight from the central top of the plate, then fasten
securely the plate with the attachment steel nail.
3.Find the wall hole location A/C using a measuring tape.

Table of Contents

Related product manuals