SERVICE MANUAL 
Model: CFE629CW 
17
Issue  2009-12-23 
Rev.  Ref0912S021V0 
4-3. Self test model  
TEST1:Press the TEST key on the power board to enter the (PULL DOWN MODE), the door display 
panel displays T1 T1 and the refrigerator enters forced refrigeration state: the compressor 
operates normally, the fan runs at high speed, and the defrosting heating wire is disconnected. 
This can be used to test the refrigeration performance.   
TEST2:Press TEST key again in TEST1 MODE to enter the (FORCED DEFROSTING MODE). It will 
act depending on the temperature sensed by the defrosting sensor When the temperature 
sensed by the defrosting sensor is over 10 , the heating wire will exit the (FORCED ℃
DEFROSTING MODE)after 20s’ heating When the temperature sensed by the defrosting 
sensor is below 10 , the heating wire will heat continuously until the temp℃ erature sensed by 
the sensor reaches 7  In the (FORCED DEFROSTING MODE), the door display panel ℃
displays T2 T2, the refrigerator conducts forced defrosting, the compressor and the fan are 
turned off, and the defrosting heating wire is turned on. At this moment, you can test the power 
of the defrosting heating wire and it should be 153±15W. 
Chapter 5 Control principle of electronic component 
5-1. Air Escaper   
(1)  The refrigeration air door is controlled with the fridge storage temperature sensor R SNR. 
(2)  The air door is closed from the beginning of defrosting until 15 minutes after the defrosting is 
finished. 
(3) Upon initial powering on or resetting of the control panel, the air door conducts a 
close-and-open cycle before acting according to the control conditions in item (1). 
(4)  The air door will be forced to conduct an open-and-close cycle if it has been closed for 1 
hour. After that, its closing/opening will be controlled by R SNR. 
(5)  If the temperature is still rising (or dropping) within 10 minutes after opening (or closing) of 
the air door, it will open (or close) once again. 
  5-2. Control Principle of the Fan 
The freezer fan is controlled by the control panel according to the following conditions. The DC 
fan’s rotation speed is regulated with PWM mode and the AC fan operates directly.   
(1)  ON/OFF condition of the freezer fan (The control mode of the DC fan is listed in the table below. 
The AC fan runs under condition ON and stops running under condition OFF): 
(2)  When the fridge storage compartment door is opened, the freezer fan will run and the refrigeration 
air door will open. After 2 minutes, the refrigeration air door will close; 
(3)  When the freezer storage compartment door is open, the freezer fan will not run; 
(4)  Conditions for judging LOCK of the freezer fan: If the rotation speed of the fan is less than 
300RPM or the fan does not run and the state has persisted for over 30 seconds, a freezer fan 
malfunction will be displayed. Normal display will be recovered after it becomes normal.