Enter Fault Retrieval Mode to check for codes F350/F352 indicating blower issues.
Use Test Mode to verify blower rotation through the vent trim.
Safely disconnect power and remove covers to access the fan motor area.
Check blower wheel for obstructions and ensure wiring is clear of the motor shaft.
Inspect blower motor wire connections and the six-pin connector for proper engagement.
Verify blower operation and check for insulation binding after powering up.
Test line voltage at the blower and ERC; replace machine board if voltage is absent.
Replace the blower tangential assembly (WB26X29060) if line voltage is present.
Remove blower assembly, transfer sensor board, and disconnect motor leads.
Install the replacement blower assembly, connecting wires and securing it properly.
Reinstall all removed exterior parts including guards, trim, and Maintop.
Power on and test blower operation, followed by a self-clean cycle test.
Enter Fault Retrieval Mode to check for codes F350/F352 indicating blower issues.
Use Test Mode to verify blower rotation through the vent trim.
Safely disconnect power and remove covers to access the fan motor area.
Check blower wheel for obstructions and ensure wiring is clear of the motor shaft.
Inspect blower motor wire connections and the six-pin connector for proper engagement.
Verify blower operation and check for insulation binding after powering up.
Test line voltage at the blower and ERC; replace machine board if voltage is absent.
Replace the blower tangential assembly (WB26X29060) if line voltage is present.
Remove blower assembly, transfer sensor board, and disconnect motor leads.
Install the replacement blower assembly, connecting wires and securing it properly.
Reinstall all removed exterior parts including guards, trim, and Maintop.
Power on and test blower operation, followed by a self-clean cycle test.